نتایج جستجو برای: fetal ecg extraction
تعداد نتایج: 275422 فیلتر نتایج به سال:
In this paper, we propose a technique of artificial intelligence called adaptive neuro fuzzy inference system (ANFIS) for canceling maternal electrocardiogram (MECG) in fetal electrocardiogram extraction (FECG).This technique is used to estimate the MECG present in the abdominal signal of a pregnant woman. The FECG is then extracted by subtracting the estimated MECG from the abdominal signal. P...
INTRODUCTION Fetal distress is a result of acute or chronic disturbances in the system of "mother-placenta-fetus" in pre-eclampsia (PE). The aim of the investigation was to compare the accuracy of antenatal fetal distress diagnostics in cases of traditional cardiotocography (CTG) waveform evaluation and analysis of morphological non-invasive electrocardiogram (ECG) parameters in anterpartum pat...
Fetal well-being was estimated by the enlargement of maternal abdomen, palpation of fetus on the abdomen, maternal perception of fetal kicking, and listening to fetal heart sound with obstetric stethoscope, in old age. Antique diagnosis of fetal life was fetal QRS found on limb lead electrocardiogram (ECG) studied by Cremer, which was progressed to fetal ECG amplifier composed of vacuum tube re...
Fetal Electrocardiogram Extraction (FECG) identifies the congenital heart problems at the earlier stage. The major problem in the non invasive procedure is the extraction of FECG from Maternal ECG (MECG) and many interferences. The proposed methods (i) Combination of Adaptive Neuro Fuzzy Inference (ANFIS) and Fractional spline wavelet (ii) Combination of Fractional spline wavelet and ANFIS (iii...
This paper utilises the distinctive transient pulse feature of the Third-Order Cumulant Diagonal Slice (TOCDS) of ECG signals to detect the number of occurrences of fetal heart beats during each of the maternal cycles. The fetal ECG signal is a comparatively weak signal (less than 20 percent of the mother ECG) and often embedded in noise. The fetal heart rate (FHR) lies in the range from 1.3 Hz...
The electric fetal heart activity was firstly recorded as tiny deflections on maternal limb lead electrocardifogram (ECG) by Cremer [1], direct lead fetal ECG with needle electrode by Caldeyro-Barcia et al. [2] and with scalp lead clip electrode by Hon [3]. Indirect maternal abdominal lead fetal ECG (fECG) was recorded by Maeda and Nakano [4] and others. Intrapartum fetal heart rate (FHR) was m...
We apply a locally linear projection technique which has been developed for noise reduction in deterministically chaotic signals to extract the fetal component from scalar maternal electrocardiographic (ECG) recordings. Although we do not expect the maternal ECG to be deterministic chaotic, typical signals are eeectively connned to a lower dimensional manifold when embedded in delay space. The ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید