نتایج جستجو برای: femoral fixation

تعداد نتایج: 90344  

2011
Yevgeniy Palatnik S. Robert Rozbruch

Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety...

2010
Maya E. Pring Mark Adamczyk Harish S. Hosalkar Tracey P. Bastrom C. Douglas Wallace Peter O. Newton

Purpose In situ fixation for mild to moderate slipped capital femoral epiphysis (SCFE) remains an acceptable treatment methodology in most centers. Satisfactory fixation results have been reported with the procedure using either the fracture table or radiolucent table, both of which allow the hip to be imaged during the procedure. The position of the pin within the center of the femoral head is...

2017
Shunsuke Asakawa Takeo Mammoto Atsushi Hirano

We present a rare clinical case of a 90-year-old female who sustained a proximal femoral neck fracture following long-standing hip arthrodesis. Since the fracture occurred relatively proximally and involved the pelvis, double-plate fixation was chosen to achieve rigid fixation. The reconstruction plate was placed at the posterior and anterior columns individually through single vertical incisio...

Journal: :Acta orthopaedica Belgica 2013
Richard P Walter Robert S Jeffery Benjamin Holroyd

Progression of slipped capital femoral epiphysis following in situ screw fixation typically occurs through loosening of the screw in the metaphysis. Epiphyseal migration off the screw due to physeal growth is rare. We report epiphyseal migration off bilateral screws in a child undergoing thyroid replacement therapy. Patients with mild and moderate slipped capital femoral epiphysis and endocrine...

Journal: :The Journal of bone and joint surgery. American volume 2010
Leonhard E Ramseier Joseph A Janicki Shannon Weir Unni G Narayanan

BACKGROUND The optimal management of femoral fractures in adolescents is controversial. This study was performed to compare the results and complications of four methods of fixation and to determine the factors related to those complications. METHODS We conducted a retrospective cohort study of 194 diaphyseal femoral fractures in 189 children and adolescents treated with elastic stable intram...

Journal: :Journal of orthopaedic surgery 2014
Chandra Prakash Pal Binod Kumar Karuna Shankar Dinkar Pulkesh Singh Harish Kumar R K Goyal

PURPOSE To review the outcomes of fixation with cancellous screws and fibular strut grafts for neglected femoral neck fractures. METHODS 44 men and 28 women aged 17 to 50 years with neglected femoral neck fractures of the subcapital (n=12), transcervical (n=57), or basal (n=3) types underwent closed (n=39) or open (n=33) reduction and fixation with a single cancellous screw with double fibula...

2010
John A. Scolaro Samir Mehta

2 Department of Orthopaedic Surgery, Harborview Medical Center, Seattle, WA Femoral neck fractures are associated with a high degree of morbidity in patients of any age, but urgent attention is given to fractures in the young patient due to complications such as femoral head osseous necrosis, fracture nonunion, or post traumatic hip arthritis. Anatomic open reduction with stable internal fixati...

Journal: :Orthopedics 2014
Tao Wang Jun-Ying Sun Guo-Chun Zha Tao Jiang Zhen-Jun You De-Jing Yuan

Femoral head necrosis is a rare but devastating complication following femoral neck fracture. The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. The aim of this study was to analyze the risk factors for femoral head necrosis after internal fixation in femoral neck fracture. This retrospective stu...

2016
Rajarajan Nagu Sakthivel Balaji Ponna puvula Subramanyam Vijayan Balakrishnan

The first efforts on treating hip fractures concentrated on alignment of fracture fragments by traction and closed reduction. The reduction was maintained by long term traction, spica casts or internal fixation. However, despite the most accurate anatomic alignment and most rigid fragment fixation, many patients failed to regain normal use of their hips. Non-union of the femoral neck, avascular...

2015
Cengiz Isik Tuhan Kurtulmus Necdet Saglam Gursel Saka Fuat Akpinar Hakan Sarman

OBJECTIVE To evaluate the effectiveness of intramedullary fixation using the Kirschner-wire (K-wire) compared to the titanium elastic nail (TEN) in pediatric femoral shaft fractures. METHODS A sample of 42 pediatric patients with a mean age of 6.55±2.42 years (range 4-11 years) presenting femoral shaft fractures underwent intramedullary fixation using the K-wire or TEN. RESULTS There was no...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید