Journal: :Physics in medicine and biology 2009
G G Echner W Kilby M Lee E Earnst S Sayeh A Schlaefer B Rhein J R Dooley C Lang O Blanck E Lessard C R Maurer W Schlegel

Robotic radiosurgery using more than one circular collimator can improve treatment plan quality and reduce total monitor units (MU). The rationale for an iris collimator that allows the field size to be varied during treatment delivery is to enable the benefits of multiple-field-size treatments to be realized with no increase in treatment time due to collimator exchange or multiple traversals o...

Journal: :journal of biomedical physics and engineering 0
m robatjazi tehran university of medical sciences k tanha bushehr university of medical sciences s r mahdavi iran university of medical sciences h r baghani shahid beheshti university h r mirzaei shahid beheshti university of medical sciences m mousavi tehran university of medical sciences

background: one of the main problems of dedicated iort accelerators is to determine dosimetric characteristics of the electron beams. monte carlo simulation of iort accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. materials and methods: liac accelerator head was modeled using the beamnrcmonte carlo simulation system. phase-space files were generated a...

Journal: :International journal of radiation oncology, biology, physics 2010
Pengpeng Zhang Laura Happersett Yingli Yang Yoshiya Yamada Gig Mageras Margie Hunt

PURPOSE To develop a collimator trajectory optimization paradigm for volumetric modulated arc therapy (VMAT) and evaluate this technique in paraspinal stereotactic body radiation therapy (SBRT). METHOD AND MATERIALS We propose a novel VMAT paradigm, Coll-VMAT, which integrates collimator rotation with synchronized gantry rotation, multileaf collimator (MLC) motion, and dose-rate modulation. A...

2001
R. Brinkmann Pantaleo Raimondi Andrei Seryi

In the Beam Delivery Systems (BDS) for linear colliders that have been designed or built, collimators (or scrapers) are used to suppress backgrounds due to the beam halo. Off-energy and off-axis particles are stopped on the collimator jaws, physically limiting the acceptance of the system. This concept does not scale well to higher beam energy, higher intensity or lower emittance. The increased...

Journal: :Biomedical optics express 2016
Wei Zhang Dianwen Zhu Michael Lun Changqing Li

X-ray luminescence computed tomography (XLCT) is an emerging hybrid imaging modality, which is able to improve the spatial resolution of optical imaging to hundreds of micrometers for deep targets by using superfine X-ray pencil beams. However, due to the low X-ray photon utilization efficiency in a single pinhole collimator based XLCT, it takes a long time to acquire measurement data. Herein, ...

Journal: :Journal of radiation research 2001
M Ishikawa T Kobayashi Y Sakurai K Kanda

Because background radiation in an irradiation room creates a problem with the PG-SPECT (Prompt Gamma-ray Single Photon Emission Computed Tomography) system, which evaluates the absorbed dose for the Boron Neutron Capture Therapy treatment, optimization of a collimator system was performed while taking the shielding of background gamma-rays into consideration. Assuming that a parallel-beam coll...

1969
A. Barna E. L. Cisneros C. Dale A. Johnson

The paper describes the electronic instrumentation for a nonintercepting gamma-beam monitor in use at the 82” bubble chamber at the Stanford Linear Accelerator Center. The position and the intensity of the beam are monitored by four shower-counters placed behind a 2-mm collimator. The bubble chamber flash-illumination and cameraadvance are inhibited when the beam is not centered within 0.5 mm.

2011
G. Stancari G. Annala T. R. Johnson G. W. Saewert V. Shiltsev D. A. Still A. Valishev

Recent experimental studies at the Fermilab Tevatron collider have shown that magnetically confined hollow electron beams can act as a new kind of collimator for highintensity beams in storage rings. In a hollow electron beam collimator, electrons enclose the circulating beam. Their electric charge kicks halo particles transversely. If their distribution is axially symmetric, the beam core is u...

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

Journal: :Medical physics 2000
J Dai Y Zhu

This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of the dose gradients of all beams be zero everywhere in the target volume. This ...