نتایج جستجو برای: electronic portal imaging device radiation therapy

تعداد نتایج: 2055089  

2000
Sophie Lavertu Louis-Martin Girouard Jean Pouliot

Purpose: The goals of this study were to evaluate the use of electronic portal imaging device (EPID) paper images as off-line veri®cation tools and to assess the feasibility of replacing portal ®lms by EPID printed images. Materials and methods: Electronic portal images were acquired using a video-based imaging system. After contrast enhancement, these images were printed and compared to portal...

Journal: :Medical physics 2001
M G Herman J M Balter D A Jaffray K P McGee P Munro S Shalev M Van Herk J W Wong

AAPM Task Group 58 was created to provide materials to help the medical physicist and colleagues succeed in the clinical implementation of electronic portal imaging devices (EPIDs) in radiation oncology. This complex technology has matured over the past decade and is capable of being integrated into routine practice. However, the difficulties encountered during the specification, installation, ...

E. Bezak, M. Mohammadi,

ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...

Journal: :iranian journal of radiation research 0
m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia e. bezak department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia

abstract background: for treatment verification in radiation therapy. several physical characteristics of scanningliquid filled ionization chamber epid (slic-epid) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.electronic portal imaging devices (epids) have found an outstanding positionmaterials and methods: equilibrium, 1-30 mm white water mat...

F Shahedi, H Gholamhosseinian M H Bahreyni M Mohammadi, M Momennezhad, R Salek, S Bayani, S M Hashemi, S Nasseri

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

Hajareh Ghaderzadeh Hamed Ghaffari Mahdieh Afkhami, Mohammad Haghparast Seyed Rabi Mahdavi

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید