نتایج جستجو برای: egsnrc code
تعداد نتایج: 167957 فیلتر نتایج به سال:
Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-towater in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widely...
In its recent recommendations the ICRP adopted two voxel models of an adult male and an adult female to be used for the forthcoming update of organ dose conversion coefficients. These voxel models are representative of an average population, i.e. they resemble the ICRP reference anatomical data with respect to their external dimensions and their organ masses and were constructed for this purpos...
Recent standard dosimetry protocols recommend that plane-parallel ionization chambers be used in the measurements of depth-dose distributions or the calibration of low-energy electron beams with beam quality R50 <4 g/cm2. In electron dosimetry protocols with the plane-parallel chambers, the wall correction factor, Pwall, in water is assumed to be unity and the replacement correction factor, Pre...
*Corresponding author: Dr. Nasrollah Jabbari, Department of Medical Physics and Imaging, Faculty of Para medicine, Urmia University of Medical Sciences, Urmia, Iran Fax: +98 441 2770047 E-mail: [email protected] Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. Th...
Kilovoltage (kV) cone beam computed tomography (CBCT) images suffer from a substantial scatter contribution. In this study, Monte Carlo (MC) simulations are used to evaluate the scattered radiation present in projection images. These predicted scatter distributions are also used as a scatter correction technique. Images were acquired using a kV CBCT bench top system. The EGSnrc MC code was used...
Objetivo: Este artigo apresenta uma forma de se obterem estimativas de dose em pacientes submetidos a tratamentos radioterápicos a partir da análise das regiões de interesse em imagens de medicina nuclear. Materiais e Métodos: Foi desenvolvido o software denominado DoRadIo (Dosimetria das Radiações Ionizantes), que recebe as informações sobre os órgãos fontes e o órgão alvo e retorna resultados...
*Corresponding author: Dr. Tayyeb Allahverdi Pourfallah, Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Fax: +98 21 88973653 E-mail: [email protected] Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equi...
A new method is proposed for scatter-correction of cone-beam CT images. A coarse reconstruction is used in initial iteration steps. Modelling of the x-ray tube spectra and detector response are included in the algorithm. Photon diffusion inside the imaging subject is calculated using the Monte Carlo method. Photon scoring at the detector is calculated using forced detection to a fixed set of no...
This paper presents investigations of thimble ionization chamber response in medium-energy kilovoltage x-ray beams (70-280 kVp, 0.09-3.40 mm Cu HVL). Two thimble ionization chambers (PTW30015 and PTW30016) were investigated, regarding the influence of the central electrode dimensions made of aluminum. Measurements were carried out in photon fields of different beam quality. Corresponding Monte ...
Existing data used to calculate the barrier transmission of scattered radiation from computed tomography (CT) are based on primary beam CT energy spectra. This study uses the EGSnrc Monte Carlo system and Epp user code to determine the energy spectra of CT scatter from four different primary CT beams passing through an ICRP 110 male reference phantom. Each scatter spectrum was used as a broad-b...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید