نتایج جستجو برای: cr 39 dosimeter
تعداد نتایج: 143712 فیلتر نتایج به سال:
A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the backgrou...
When used at facilities like OMEGA and the NIF, CR-39 is exposed to high vacuum environments before and after irradiation by charged particles and neutrons. Using an electrostatic linear accelerator at MIT, studies have been conducted to investigate the effects of high vacuum exposure on the sensitivity of CR-39 to fusion protons in the ~1-9 MeV energy range. High vacuum conditions, of order 10...
Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...
background: several epidemiological studies conducted on underground miner’s show that exposure to elevated levels of radioactive radon gas is expected to increase the risk of lung cancer. relative risk of lung cancer is almost linear with radon exposure. elevated concentrations of radon are not only reported within mines but also for closed indoor environment of general public houses. measurem...
Introduction: Natural radioactivity in the soil is considered a major indicator of radiological contamination. Primordial radionuclides are the main source of natural radioactivity. Natural radioactivity transfers radionuclides into the environment and poses radiation hazards to people's health. Therefore, the present study aimed to determine the radon concentration an...
Alpha-particle radiobiological experiments involve irradiating cells with alpha particles and require accurate positions where the alpha particles hit the cells. In the present work, we prepared thin CR-39 detectors from commercially available CR-39 SSNTDs with a thickness of 100 lm by etching them in 1 N NaOH/ethanol at 40 C to below 20 lm. The desired final thickness was achieved within 8 h. ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید