نتایج جستجو برای: contrast sensitivity functions

تعداد نتایج: 1162208  

Journal: :Trends in neurosciences 2001
E Castet S Jeanjean G S Masson

In their recent review article on intra-saccadic visual perception, Ross et al. 1 concluded that motion of the world during saccades is not perceived because motion sensitivity is selectively reduced by an extra-retinal signal – although they concede that visual masking might also play an important role. However, we believe that extant data favour a more parsimonious interpretation, namely that...

Journal: :Investigative ophthalmology & visual science 1979
K H Hagemans G J van der Wildt

The contrast sensitivity function of both eyes of subjects with functional amblyopia has been measured. A clinically significant difference was found between the amblyopic and the normal eye. It appears that the functionally amblyopic eye takes more information from the peripheral parts of the stimulus than does the normal eye. The sensitivity of the normal eye increases linearly with increasin...

Journal: :Psychonomic bulletin & review 2014
Zachary J J Roper Shaun P Vecera

Perceptual load theory accounts for many attentional phenomena; however, its mechanism remains elusive because it invokes underspecified attentional resources. Recent dual-task evidence has revealed that a concurrent visual short-term memory (VSTM) load slows visual search and reduces contrast sensitivity, but it is unknown whether a VSTM load also constricts attention in a canonical perceptual...

Journal: :Vision Research 2004
M. C. Morrone V. Denti D. Spinelli

We used an interference paradigm to investigate whether attention is attribute-specific at early levels of visual processing. We show that the peripheral increment thresholds for luminance contrast deteriorate when the observer is currently performing another luminance (form or contrast) discrimination task in central view, but not when he or she is performing a color discrimination task. Simil...

Journal: :Journal of clinical and experimental neuropsychology 2001
M P van Boxtel M P ten Tusscher J F Metsemakers B Willems J Jolles

It is unknown to what extent the performance on the Stroop color-word test is affected by reduced visual function in older individuals. We tested the impact of common deficiencies in visual function (reduced distant and close acuity, reduced contrast sensitivity, and color weakness) on Stroop performance among 821 normal individuals aged 53 and older. After adjustment for age, sex, and educatio...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 1999
P J Bennett A B Sekuler L Ozin

Contrast sensitivity under photopic conditions declines with age; however, the cause of this decline remains unknown. To address this issue, we measured detection thresholds for sine wave gratings in noise, under various conditions of spatial-frequency uncertainty, and estimated observers' internal noise and calculation efficiency. Statistical analyses revealed that efficiencies were lower for ...

Journal: :Vision Research 1999
Thom Carney Stanley A. Klein

Bisection is one of several spatial localization tasks that achieve hyperacuity performance levels. We find that optimal bisection thresholds, and hyperacuity tasks in general, are no better than might be expected from simple contrast detection and discrimination performance. The three-line bisection task can be described in terms of the test-pedestal paradigm where the test pattern is a horizo...

Journal: :Vision Research 2005
Franco Pestilli Marisa Carrasco

Transient covert attention increases contrast sensitivity at the target location with an informative spatial cue. Here we explored whether an uninformative spatial cue (50% valid with two possible locations) also increases contrast sensitivity and whether contrast sensitivity is altered at the uncued location as compared to the neutral condition. For all four observers, transient covert attenti...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 1997
B Spehar Q Zaidi

The shape of the temporal contrast-sensitivity function at low temporal frequencies is sensitive to the relative luminance of the test and the surround. We show that this effect is due to greater sensitivity, in different conditions, either to the internal luminance modulation in the test or to temporal changes in the spatial contrast at the edge of the test. We measured temporal contrast sensi...

Journal: :Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas 2004
N A Santos M L B Simas R M T B L Nogueira

The aim of the present study was to measure contrast sensitivity curves for angular frequencies in the range between 2 and 96 cycles/360 masculine in older human adult volunteers and to compare these measurements with the more usual contrast sensitivity functions for sine-wave gratings. All subjects were free of identifiable ocular disease and had normal acuity. We measured the contrast thresho...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید