نتایج جستجو برای: concrete coupled shear wall

تعداد نتایج: 505861  

The addition of steel fibers into concrete improves the postcracking tensile strength of hardened concrete and hence significantly enhances the shear strength of reinforced concrete reinforced concrete beams. However, developing an accurate model for predicting the shear strength of steel fiber reinforced concrete (SFRC) beams is a challenging task as there are several parameters such as the co...

2012
S. Simonini R. Constantin A. Rutenberg K. Beyer

Midto high-rise buildings are often braced by slender reinforced concrete (RC) walls, which are coupled by RC floor diaphragms. In design it is typically assumed that the walls act independently and the design base shear demand is computed neglecting any compatibility forces between the walls. Pushover analysis of systems comprising walls of different lengths have, however, shown that large com...

2013
Peng Zhang

Plastic concrete consists of aggregates, cement, water and bentonite, mixed at a high water cement ratio, to produce a ductile material. It is used for creating an impermeable barrier (cut-off wall) for containment of contaminated sites or seepage control in highly permeable dam foundations. The effects of water to binder ratio and clay dosage on mechanical properties of plastic concrete were i...

Journal: :Buildings 2022

The coupled steel plate and reinforced concrete (C-SPRC) composite wall is a new type of coupled-wall system consisting coupling beams (SCBs) that join two SPRC walls where the shear (SPSW) embedded in RC wall. Although C-SPRC has been extensively constructed high-rise buildings seismic regions, research on its behavior rarely reported. No code provisions are available for directly guiding prel...

E. Zamani H. Shariatmadar, M. Khatamirad

In reinforced concrete design, there are situations where transfer of shear across a specific plane needs to be considered. Examples of such situation include corbels, bearing shoes, ledger beam bearing, and a host of connection between precast concrete elements. In this study, the shear transfer behavior of reinforced concrete is investigated experimentally by conducting test on 6 precracked p...

S. M. Zahrai and B. Rad,

In recent years, destructive earthquakes have shown the deficiencies of the existing buildings. One of the most effective mechanisms for dissipating the earthquake energy is inelastic deformation of the steel components. The objective of this research is to study the application of metallic dampers for dissipation of the earthquake energy and to investigate the behavior of concrete structures i...

S. M. Zahrai and B. Rad,

In recent years, destructive earthquakes have shown the deficiencies of the existing buildings. One of the most effective mechanisms for dissipating the earthquake energy is inelastic deformation of the steel components. The objective of this research is to study the application of metallic dampers for dissipation of the earthquake energy and to investigate the behavior of concrete structures i...

Self-centering rocking walls are known as viable alternatives to typical shear walls, as they provide a number of solutions for eliminating seismic flaws of conventional designs. These rocking walls have a generally positive impact on the seismic behavior of structural systems, but their design makes them susceptible to concrete crushing around their base, which can lead to significantly advers...

2012
P. Hannewald K. Beyer

Plastic hinge models are widely used in earthquake engineering to predict the load-deformation relationships of reinforced concrete members. For the seismic assessment of bridges, it is appealing to use those relatively simple models if the response is predicted with sufficient accuracy. The applicability of these models to wall-type bridge piers with weak seismic detailing is examined. Flexura...

2016
Hongyu Deng Baitao Sun

During the analysis of reinforced concrete structures, the infill wall is usually simplified as a diagonal inclined strut to facilitate finite element modeling calculations. However, the actual seismic damage and single frame-filled wall pushover experimental results show that when the earthquake shear force is huge, the top of the infill wall and the beam–column connections are usually, thus t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید