Objective: The radiation dosimetry is the output measurement of radiation generating source/ machine and its ambition is to ensure that the teletherapy units’ outputs are within limits. In the current article, the dosimetry of Cobalt-60 (Co 60 ) teletherapy units at Nuclear Institute of Medicine and Radiotherapy (NIMRA), Jamshoro Pakistan was studied. As Co 60 is undergo decay process, the outp...
One of the main objectives Secondary Standard Dosimetry Laboratory (SSDL) in radiotherapy dosimetry is verifying radiation dose provided to patients accurate and meets globally recognised standards. Properly calibrating therapy dosimeters used centres first step SSDL must take ensure this goal attained. This study analyses calibration coefficients long-term stability calibrated by Nuklear Malay...
The solid state active detectors, widely used for conventional radiotherapy, such as diamond detectors (DD) and diodes may be attractive tools also in dosimetry of therapeutic proton beams. Diodes are broadly applied in oncology clinics and routinely used for in-vivo dosimetry [1, 8]. These real-time detectors are rugged, relatively inexpensive and provide on-line readings, what allows for quic...
Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...
PURPOSE The purpose of this study was to compare the surface dose of 7-field IMRT (7 F-IMRT), tangential beam IMRT (TB-IMRT), and tangential beam 3D-CRT (3D-CRT) of breast cancer patients receiving adjuvant radiotherapy by means of in vivo GafChromic film dosimetry. MATERIAL AND METHODS Breast cancer patients receiving adjuvant radiotherapy of the whole breast or the chest wall were eligible ...
Background and purpose: In-vivo dosimetry is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the entrance doses without the build-up cap for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS). Materials and methods: The stu...
Optically stimulated luminescent detectors, which are widely used in radiation protection, offer a number of potential advantages for application in radiation therapy dosimetry. Their introduction into this field has been somewhat hampered by the lack of information on their radiation response in megavoltage beams. Here the response of a commercially available optically stimulated luminescent d...
PURPOSE Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific (192)Ir, (137)Cs, and (60)Co source models. METHODS This report has be...
This work considers a previously overlooked uncertainty present in film dosimetry which results from moderate curvature of films during the scanning process. Small film samples are particularly susceptible to film curling which may be undetected or deemed insignificant. In this study, we consider test cases with controlled induced curvature of film and with film raised horizontally above the sc...
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...