Introduction Weaning from mechanical ventilation is defined as the process of release of ventilatory support and how the evaluation of this phase is conducted in the Spontaneous Breathing Test (SBT). One of the most used modes of SBT is the Continuous Positive Airway Pressure (CPAP). However, together with the mechanical ventilation modes it can be used the Automatic Tube Compensation (ATC), wh...
background: increasedlife expectancy in populations has brought along specific new scenarios in the fields of medicine for the elderly; prevalence of physical complications such as edentulism and patients with dentures is growing. management of anesthesia and ventilation in this group of patients has turned into a great challenge. some researchers suggest dentures to be left in place during bag...
The deflation limb of the pressure-volume relationship in infants during high-frequency ventilation.
RATIONALE The importance of applying high-frequency oscillatory ventilation with a high lung volume strategy in infants is well established. Currently, a lack of reliable methods for assessing lung volume limits clinicians' ability to achieve the optimum volume range. OBJECTIVES To map the pressure-volume relationship of the lung during high-frequency oscillatory ventilation in infants, to de...
Airway pressure release ventilation (APRV) is a ventilator mode which has demonstrated potential benefits in acute respiratory distress syndrome (ARDS) patients. We therefore sought to compare relevant pulmonary data and safety outcomes of this mode to the conventional ventilation and sustained inflation. Canines admitted after intravenous injection of oleic acid requiring mechanical ventilatio...
OBJECTIVES To measure airway pressures during closed system suctioning with the ventilator set to three differing modes of ventilation. METHODS Closed system suctioning was conducted in 16 patients following cardiac surgery. Suctioning was performed using a 14 French catheter with a vacuum level of -500 cmH2O through an 8.0 mm internal diameter endotracheal tube. The lungs were mechanically v...
Although lifesaving, mechanical ventilation can itself be responsible for damage to lung parenchyma. This ventilator-induced lung injury is especially observed in already injured lungs of patients with ARDS. New ventilatory approaches are needed to safely treat patients with ARDS, and recent studies have suggested the potential utility of open-lung strategies. Airway pressure release ventilatio...
Background: Cuffed pharyngeal tube is a device designed for ventilation of anesthetized patients. CPT has advantages over face mask including: maintaining of face mask can be difficult and boring after several minutes and mobility of the practitioner is reduced due to involvement of hands. Mask pressure can cause soft tissue and nerve damage around the nose. Anesthetic gas leakage from the mask...
OBJECTIVES To evaluate the use of specific compliance (static compliance/functional residual capacity) to adjust mean airway pressure, resulting in optimal gas exchange during high-frequency oscillatory ventilation in a surfactant-deficient newborn piglet. DESIGN Prospective controlled animal study. SETTING Laboratory. SUBJECTS Eight newborn piglets at 5 days of age. BACKGROUND High-fre...
A 4.2-kg full-term male infant underwent treatment of acute respiratory distress as a result of gross bilateral pneumothoraces, pneumomediastinum and interstitial emphysema. When a trial of continuous positive airway pressure failed conventional intermittent positive pressure ventilation was instituted, but this also failed to achieve satisfactory ventilation at a respiratory frequency of 60 b....