Journal: :Physics in medicine and biology 2014
Jean Provost Clement Papadacci Juan Esteban Arango Marion Imbault Mathias Fink Jean-Luc Gennisson Mickael Tanter Mathieu Pernot

Very high frame rate ultrasound imaging has recently allowed for the extension of the applications of echography to new fields of study such as the functional imaging of the brain, cardiac electrophysiology, and the quantitative imaging of the intrinsic mechanical properties of tumors, to name a few, non-invasively and in real time. In this study, we present the first implementation of Ultrafas...

Journal: :American journal of surgery 2006
Oren M Tepper Kevin Small Lauren Rudolph Mihye Choi Nolan Karp

Three-dimensional (3D) imaging technology currently is used by various commercial industries as a method for analyzing objects and shapes. Recent work from our group and others offer data to support the use of 3D imaging as a valuable tool in aesthetic and reconstructive breast surgery. We have developed a system for creating 3D breast models that provides clinical data that can help guide surg...

2013
Akihisa Takeuchi Kentaro Uesugi Yoshio Suzuki

A three-dimensional (3D) X-ray tomographic micro-imaging system has been developed. The optical system is based on a scanning-imaging X-ray microscope (SIXM) optics, which is a hybrid system consisting of a scanning microscope optics with a one-dimensional (1D) focusing (line-focusing) device and an imaging microscope optics with a 1D objective. In the SIXM system, each 1D dataset of a two-dime...

2014
B. Verney M. Akhloufi O. Aubreton

3D scanning and modeling is used in a wide range of applications like manufacturing, aerospace, security, biomedicine, etc. This kind of systems allows the scanning of a 3D point cloud that can be meshed and rendered in order to obtain a complete 3D model. However, 3D vision cannot detect subsurface defects. This later can be achieved using other imaging modalities, like thermal infrared imagin...

2012
Bo Wang Liangzhong Xiang Max S. Jiang Jianjun Yang Qizhi Zhang Paul R. Carney Huabei Jiang

A real-time three-dimensional (3D) photoacoustic imaging system was developed for epilepsy imaging in small animals. The system is based on a spherical array containing 192 transducers with a 5 MHz central frequency. The signals from the 192 transducers are amplified by 16 homemade preamplifier boards with 26 dB and multiplexed into a 64 channel data acquisition system. It can record a complete...

2002
Kazutaka Tonsho Yoshinori Akao Norimichi Tsumura Yoichi Miyake

In recent years, it is required to develop a system for 3D capture of archives in museums and galleries. In visualizing of 3D object, it is important to reproduce both color and glossiness accurately. Our final goal is to construct digital archival systems in museum and internet or virtual museum via World Wide Web. To achieve our goal, we have developed gonio-photometric imaging system by usin...

2006
Thomas T. Lu Tien-Hsin Chao

The paper presents an advanced 3D imaging system based on a combination of stereo vision and light projection methods. A single digital camera is used to take only one shot of the object and reconstruct the 3D model of an object. The stereo vision is achieved by employing a prism and mirror setup to split the views and combine them side by side in the camera. The advantage of this setup is its ...

Journal: :Applied optics 2013
Jaehyuk Jang Jongwoo Hong Hwi Kim Joonku Hahn

A light-folded projection three-dimensional (3D) display system with a single projection lens and a rectangular light tunnel which is composed of four folding mirrors on its inside walls is proposed. It is theoretically shown through the Wigner distribution function analysis that the proposed system can generate the same light field effectively as that of the conventional projection-type multiv...

Journal: :Circulation 1998
T Shiota M Jones M Chikada C E Fleishman J B Castellucci B Cotter A N DeMaria O T von Ramm J Kisslo T Ryan D J Sahn

BACKGROUND The lack of a suitable noninvasive method for assessing right ventricular (RV) volume and function has been a major deficiency of two-dimensional (2D) echocardiography. The aim of our animal study was to test a new real-time three-dimensional (3D) echo imaging system for evaluating RV stroke volumes. METHODS AND RESULTS Three to 6 months before hemodynamic and 3D ultrasonic study, ...

Journal: :Applied optics 2009
Jae-Hyun Jung Yunhee Kim Youngmin Kim Joohwan Kim Keehoon Hong Byoungho Lee

We propose a thin and compact integral imaging system using electroluminescent (EL) films as backlight. EL film has the advantage that it can operate continuously even when it is cut or punctured. Using this characteristic, we generate an array of pinholes on EL film to form a point light-source array for reconstructing three-dimensional (3D) images based on integral imaging. The EL pinhole fil...