نتایج جستجو برای: 3d film dosimetry dvh

تعداد نتایج: 284641  

2006
Chengyu Shi Nikos Papanikolaou Yulong Yan Xuejun Weng gyu Jiang

In our institution, patient specific quality assurance (QA) for intensity modulated radiation therapy (IMRT) is usually performed by measuring the dose to a point using an ion chamber and by measuring the dose to a plane using film. In order to perform absolute dose comparison measurements using film, an accurate calibration curve should be used. In this paper, we investigated the film response...

Journal: :Physics in medicine and biology 2014
A Subiel V Moskvin G H Welsh S Cipiccia D Reboredo P Evans M Partridge C DesRosiers M P Anania A Cianchi A Mostacci E Chiadroni D Di Giovenale F Villa R Pompili M Ferrario M Belleveglia G Di Pirro G Gatti C Vaccarezza B Seitz R C Isaac E Brunetti S M Wiggins B Ersfeld M R Islam M S Mendonca A Sorensen M Boyd D A Jaroszynski

Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibrat...

Alireza Nikoofar Khadijeh Asnaashari Mahbobeh Nazarnejad, Mahdi Sadeghi Seied Rabi Mahdavi

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

2014
L J Schreiner

Since the introduction of volumetric chemical dosimetry with Fricke gel dosimeters in the 1980s, three-dimensional (3D) dosimetry has been a promising technique for the clinic, since it provides a unique methodology for 3D dose measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. In the last decad...

2014
D. E. Raeside

The field of personnel radiation monitoring is presently in a state of radical change. It appears that the unreliability of the film badge is now firmly established, bringing into question the value of much of the massive amount of personnel dosimetry data accumulated in the past three decades. This article examines the evidence "against" the film badge and reviews the comparative studies "for"...

2017
Kyle Sunderland Csaba Pinter Andras Lasso Gabor Fichtinger

PURPOSE: In radiation therapy treatment planning systems, structures are represented as parallel 2D contours. For treatment planning algorithms, structures must be converted into labelmap (i.e. 3D image denoting structure inside/outside) representations. This is often done by triangulated a surface from contours, which is converted into a binary labelmap. This surface to binary labelmap convers...

2016
M.T. Bahreyni Toossi F. Khorshidi M. Ghorbani N. Mohamadian D. Davenport

BACKGROUND EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. OBJECTIVE The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. METHODS Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose wa...

Hasan Nedaie Majid Shariari Zahra Anjomani,

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

Journal: :Applied sciences 2021

The aim of this study was to develop and apply an evaluation method for assessing the accuracy a novel 3D EPID back-projection algorithm in vivo dosimetry. Dosimetry Check (DC) 5.8 evaluated. A slab phantom homogeneously filled, or with air bone inserts, used fluence reconstruction different squared fields. VMAT plans anatomical sites were delivered on anthropomorphic phantom. Dose distribution...

C. Anu Radha, G. Arun, M. Kathirvel, S. Thirumalai Swamy, V. Subramanian,

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید