2010
Vagner Ferreira Cassola Gabriela Hoff

OBJECTIVE: To compare data regarding dosimetry and photons fluence in different breast phantoms, discussing constancy tests and dosimetry applied to mammography. MATERIALS AND METHODS: Different homogeneous breast phantoms and one anthropomorphic voxel phantom were developed for collection of data regarding total absorbed dose in the phantom, absorbed dose in the glandular tissue material-equiv...

2011
Sylvia Garny Werner Rühm Maria Zankl Franz M Wagner Herwig G Paretzke

BACKGROUND The Monte Carlo code GEANT4 was used to implement first steps towards a treatment planning program for fast-neutron therapy at the FRM II research reactor in Garching, Germany. Depth dose curves were calculated inside a water phantom using measured primary neutron and simulated primary photon spectra and compared with depth dose curves measured earlier. The calculations were performe...

2000
Richard Watts Yi Wang Priscilla A. Winchester Neil Khilnani Lawrence Yu

Introduction The relationship between noise and detectable spatial resolution is described by the Rose Model: the differentiation of a single voxel from the noise background requires a minimum signal-to-noise ratio (SNR) per voxel of 4 (1,2). This model has been widely used as a guide in x-ray imaging. This study assesses its implication for MRI and develops a guideline forkspace sampling. In k...

2018
T Rydén J Heydorn Lagerlöf J Hemmingsson I Marin J Svensson M Båth P Gjertsson P Bernhardt

BACKGROUND Full Monte Carlo (MC)-based SPECT reconstructions have a strong potential for correcting for image degrading factors, but the reconstruction times are long. The objective of this study was to develop a highly parallel Monte Carlo code for fast, ordered subset expectation maximum (OSEM) reconstructions of SPECT/CT images. The MC code was written in the Compute Unified Device Architect...

Journal: :Physics in medicine and biology 2005
Simon J Doran Liz Charles-Edwards Stefan A Reinsberg Martin O Leach

MR images are known to be distorted because of both gradient nonlinearity and imperfections in the B0 field, the latter caused either by an imperfect shim or sample-induced distortions. This paper describes in detail a method for correcting the gradient warp distortion, based on a direct field mapping using a custom-built phantom with three orthogonal grids of fluid-filled rods. The key advance...

Mahmood Allahverdi, Micaeil Mollazadeh Mohammadreza Ay Nader Riahi Alam Tayyeb Allahverdi Pourfallah,

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2010
Vincent Keereman Yves Fierens Tom Broux Yves De Deene Max Lonneux Stefaan Vandenberghe

UNLABELLED One of the challenges in PET/MRI is the derivation of an attenuation map to correct the PET image for attenuation. Different methods have been suggested for deriving the attenuation map from an MR image. Because the low signal intensity of cortical bone on images acquired with conventional MRI sequences makes it difficult to detect this tissue type, these methods rely on some sort of...

2017
Bruno Melo Mendes Iassudara Garcia de Almeida Bruno Machado Trindade Telma Cristina Ferreira Fonseca

The aim of this study was to create and test a new mice 3D-voxel phantom named DM_BRA for mice and human first-estimation radiopharmaceutical dosimetry. Previously, the article reviews the state-ofart in animal model development. Images from Digimouse CT database were used in the segmentation and on the generation of the voxelized phantom. Simulations for validation of the DM_BRA model was perf...

2010
N. Zarinabad nooralipour A. Chiribiri G. Hautvast A. V. Arujuna E. Nagel P. Batchelor

Background Accurate assessment of relative reductions in regional myocardial blood flow (MBF) is clinically important in identifying haemodynamically significant coronary artery disease. First-pass perfusion magnetic resonance imaging allows for a non-invasive and radiation free quantification of MBF. One of the advantages of MR perfusion over nuclear medicine techniques is better spatial resol...