نتایج جستجو برای: volume pulse
تعداد نتایج: 400390 فیلتر نتایج به سال:
BACKGROUND Positive end-expiratory pressure (PEEP) may reduce cardiac output and total hepatic blood flow after liver transplantation. Pulse pressure variation is useful in predicting the PEEP-induced decrease in cardiac output. The aim of the study was to examine the relationships between stroke volume variations (SVV) obtained with the Vigileo monitor (Edwards Lifesciences, Irvine, CA), and t...
OBJECTIVES Inhalant anesthesia induces dose-dependent cardiovascular depression, but whether fluid responsiveness is differentially influenced by the inhalant agent and plasma volemia remains unknown. The aim of this study was to compare the effects of isoflurane, sevoflurane and desflurane on pulse pressure variation and stroke volume variation in pigs undergoing hemorrhage. METHODS Twenty-f...
Respiratory-associated variations in stroke volume and pulse pressure are frequently used to predict the response to fluid administration. However, it has been demonstrated that low tidal volume ventilation may limit their use in patients with acute respiratory distress syndrome (ARDS). In this issue, a trial investigates the value of pulse pressure variation to predict fluid responsiveness in ...
was passed. Temperature was 99.4?F. but the pulse had risen to 102 though still of good volume. He vomited a small quantity of bilious matter. A differential leucocytic count showed 89 per cent polymorphonuclears. A provisional diagnosis of " obstruction with commencing peritonitis" was made and laparotomy decided on. At 9-30 a.m. when the patient arrived on the table his general condition was ...
introduction: transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. in this study, we compared and evaluated the treatment effects of dual frequency irradiatio...
Positive-pressure ventilation alters stroke volume by transiently increasing intrathoracic pressure and thereby decreasing preload. This phasic variation in stroke volume results in a cyclic fluctuation in arterial pressure with a phase length equal to the respiratory rate. Measuring ventilation-induced arterial pressure variation allows the clinician to predict the cardiovascular response to c...
Abstract not available
 Pulse Volume 12-14 2020-2022 p.60-68
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید