نتایج جستجو برای: transformer winding

تعداد نتایج: 16464  

1998
Robert W. Erickson Dragan Maksimovic

A general model of the mul t ip l e winding transformer and coupled inductor i s presented, in which all parameters can b e directly measured. The approach is suitable f o r all winding geometries, and s i m p l i f y i n g approximations can be easily made. This model can be applied in determination of c r o s s regulation, current ripple, and s m a l l s i g n a l dynamics of multiple-output ...

2004
Kazuhiko Sakakibara Naoki Murakami

leads and windings due t o eddy cu r ren t s induced in the conductors by t h e al ternat ing magnetic field. The leads and windings a r e connected in series, therefore, t he high-frequency resistance of t he transformer R t is An accurate, analyt ical method is proposed f o r calculating the lead and winding high-frequency resistance of complex transformer constructions. High-frequency resist...

2005
MOHAMMAD S. NADERI B. T. PHUNG MEHDI S. NADERI

In this paper a method for extracting Partial Discharge (PD) signals is introduced, which is implemented for evaluating electrical measured partial discharges on a 66 kV / 25 MVA fully interleaved winding of a power transformer. Applying wavelet transform to a signal produces a wavelet detail coefficient distribution throughout the time-scale, which depends on the mother wavelet chosen. This me...

A.A. Shayegani Akmal, Amir Mohammadirad Ramin Vakili,

Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...

Journal: :international journal of smart electrical engineering 2014
v. behjat mojtaba mahvi ebrahim rahimpour

the frequency response analysis (fra) test has been recognized as one of the sensitive tools available for detecting electrical and mechanical faults inside power transformers. however, there is still no universally systematic interpretation technique for these tests. many research efforts have employed different statistical criteria in order to aid the interpretative capability of the fra, but...

2008
Edris AGHEB Amir HAYATI SOLOOT Ehsan HASHEMI Jouya JADIDIAN Amir A. SHAYEGANI AKMAL

To study the voltage distribution in transformer windings under VFTO, a model for transformer windings has been developed based on Multi-conductor Transmission-Lines (MTLs) theory and the computing equations of the model based on FiniteDifference Time-Domain method (FDTD) is deduced. The Vector Fitting method is adopted to treat the frequency-dependent parameter by expanding the time-domain for...

2007
W. H. Tang S. He Q. H. Wu

This paper presents a new approach to identify distributed parameters of a lumped-element model for a power transformer. A simplified circuit of a lumped-element model is developed to calculate frequency responses of transformer windings in a wide range of frequency domain. In order to seek optimal parameters of the simplified circuit of the transformer, an intelligent learning technique, based...

Journal: :DEStech Transactions on Environment, Energy and Earth Science 2016

Journal: :TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES 2016

2009
Chang-Hung Hsu Yeong-Hwa Chang

In this paper, the properties of the physical and chemical materials, such as low loss amorphous HB1 core, high temperature resistance winding and insulation vegetable oil have been developed for use in liquid-immersed power transformer. The measured results of magnetic properties with different ferromagnetic materials core were obtained. Considering winding property for operation above 95°C co...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید