نتایج جستجو برای: traction force
تعداد نتایج: 197784 فیلتر نتایج به سال:
Safety recommendations for vacuum-assisted delivery focus on limiting the number of pulls and the duration of the procedure. With the introduction of the Kiwi OmniCup vacuum extractor incorporating a Traction Force Indicator, it is now possible to reliably monitor and control the amount of traction force exerted on the fetal scalp. The OmniCup was used in a prospective observational study of 11...
PDMS micropost arrays were fabricated, characterized, and used to analyze the traction force generated by vascular smooth muscle (VSM) cells. The micropost array was fabricated with diameters between 3-7μm, with edge to edge spacing of 5 and 7m, and height to diameter aspect radio up to 8. The spring constant of micropost used in cell culturing experiment is 20.94nN/m and the smallest tractio...
There is now considerable evidence of the importance of mechanical cues in neuronal development and regeneration. Motivated by the difference in the mechanical properties of the tissue environment between the peripheral (PNS) and central (CNS) nervous systems, we compare substrate-stiffness-dependent outgrowth and traction forces from PNS (dorsal root ganglion (DRG)) and CNS (hippocampal) neuro...
The interplay between cadherin- and integrin-dependent signals controls cell behavior, but the precise mechanisms that regulate the strength of adhesion to the extracellular matrix remains poorly understood. We deposited cells expressing a defined repertoire of cadherins and integrins on fibronectin (FN)-coated polyacrylamide gels (FN-PAG) and on FN-coated pillars used as a micro-force sensor a...
OBJECTIVE Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. METHODS Two extraction models were constructed to analyze the three-dimentional f...
AIMS We investigated a new lead extraction tool (Compression Coil; One-Tie, Cook Medical) in an experimental traction force study. METHODS AND RESULTS On 13 pacemaker leads (Setrox JS53, Biotronik) traction force testing was performed under different configurations. The leads were assigned to three groups: (i) traction force testing without central locking stylet support (n = 5), (ii) tractio...
[Purpose] Many patients receive intermittent cervical traction in a daily treatment setting. However, unified settings for traction force, duration, and direction have yet to be determined. Therefore, an objective index is required to determine changes in traction conditions or to indicate its effectiveness. [Subjects] Fifteen healthy males volunteers participated in this study. [Methods] The t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید