PURPOSE
To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in eyes with high hyperopia.
METHODS
We analyzed the results of 24 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of hyperopia with the goal of emmetropia. Mean follow...