نتایج جستجو برای: tibial nail length

تعداد نتایج: 331705  

Journal: :The Journal of bone and joint surgery. British volume 1997
G Sohngen

We report four patients who sustained secondary fractures of the posterior wall of the tibial shaft during the removal of one pattern of intramedullary nail after fracture healing. The cause of this complication is discussed.

Journal: :Medicinski glasnik : official publication of the Medical Association of Zenica-Doboj Canton, Bosnia and Herzegovina 2014
Dimitrios Begkas Dimitrios Katsenis Alexandros Pastroudis

AIM To evaluate the management of aseptic non-unions of the distal third of the tibial diaphysis, using static interlocking intramedullary nailing. METHODS Between January 2005 and November 2012, a total number of 42 patients who underwent surgery at our hospital for aseptic non-unions of the distal third of the tibial diaphysis, were included in our study. Preoperatively, all the patients we...

2009
Srinivasan Rajappa N Sunil Kumar

Intra-medullary nailing is a standard form of treatment for diaphyseal tibial fractures. Insertion of the nail requires threading of the nail over a smooth guide-wire. Inadvertent complications during this stage have been reported. We report a case of inadvertent penetration of the tibio-talar joint by the smooth guide wire caused by incarceration of a fracture fragment between the nail and the...

Journal: :Orthopedics 2017
Mohamed E Al-Ashhab

Management of severely comminuted, complete articular tibial pilon fractures (Rüedi and Allgöwer type III) remains a challenge, with few treatment options providing good clinical outcomes. Twenty patients with severely comminuted tibial pilon fractures underwent primary ankle arthrodesis with a retrograde calcaneal nail and autogenous fibular bone graft. The fusion rate was 100% and the varus m...

Journal: :Polish journal of veterinary sciences 2012
A Piórek Z Adamiak M Jaskólska Y Zhalniarovich

The treatment of comminuted tibial shaft fractures in canine patients is burdened by significant risk which involves bone healing complications, such as delayed bone union. Complications may result from iatrogenic damage to blood vessels during fracture stabilization. To minimize this risk, treatment methods increasingly often rely on the concept of biological osteosynthesis. One of such method...

Journal: :Injury 1999
G Li S Berven N A Athanasou A H Simpson

Bone transport is useful for the treatment of segmental defects, non-union and osteomyelitis. Bone transport has been compared to conventional techniques for the treatment of segmental defects and infection and found to provide better restoration of leg length, to need less cancellous grafting, to have fewer graft fractures and to require less operating time and hospital stay and to have a lowe...

Journal: :Orthopedics 2012
Chi-Chuan Wu Ching-Lung Tai

Because standard femoral supracondylar nails have certain disadvantages, they are often replaced by traditional femoral or tibial locked nails. The purpose of this study was to make a biomechanical comparison between both types of traditional locked nails to determine which technique was more suitable for treating unstable femoral supracondylar fractures. Fourteen left Sawbones femurs (Pacific ...

Journal: :the archives of bone and joint surgery 0
anil gupta head of department orthopedics & spinal injury govt medical college. jammu rashid anjum government medical college jammu. jammu & kashmir navdeep singh govt medical college jammu shafiq hackla government medical college jammu

background:  fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. the preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis  (mippo) procedure. however, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...

Journal: :Journal of the College of Physicians and Surgeons--Pakistan : JCPSP 2013
Irfanullah Khan Shahzad Javed Gauhar Nawaz Khan Amer Aziz

OBJECTIVE To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). STUDY DESIGN Case series. PLACE AND DURATION OF STUDY Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, fr...

Journal: :medical journal of islamic republic of iran 0
siroos malekpoor rasool-e-akram general hospital, iran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)سازمان های دیگر: rasool-e-akram general hospital mehdi moghtadaei, rasool-e-akram general hospital, iran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)سازمان های دیگر: rasool-e-akram general hospital ehsan akbarian rasool-e-akram general hospital, iran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)سازمان های دیگر: rasool-e-akram general hospital soheil hamedanchi rasool-e-akram general hospital, iran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)سازمان های دیگر: rasool-e-akram general hospital

abstract  background: reamed interlocking intramedullary nailing of the tibia is a procedure  for the treatment of a non-infected tibial non:::::union:::::. the purpose of this clinical  study was to evaluate the outcome of this method as a treatment of tibial non:::::union:::::.  methods: twenty-nine patients with non:::::union::::: after initial therapy for tibial fracture  were retrospective...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید