نتایج جستجو برای: thermoluminescent dosimeter

تعداد نتایج: 2461  

2000
I. H. Kim

INTRODUCTION Stereotactic radiotherapy has been majorly applied to the intracranial targets as primary or metastatic brain tumors, benign tumors, vascular malformations as arteriovenous malformations(AVM) or angiographically occult vascular malformations(AoVM), and functional neurologic diseases as neuralgias since 1951, when Dr. Leksell, a Swedish neurosurgeon, used radiation making intentiona...

Journal: :Journal of neurosurgery. Spine 2008
Rajesh K Bindal Sharon Glaze Meghann Ognoskie Van Tunner Robert Malone Subrata Ghosh

OBJECT Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular procedure. The technique involves use of fluoroscopy to assist with pedicle screw (PS) placement. The potential exists for both the surgeon and the patient to become exposed to significant amounts of radiation. The authors undertook this study to quantify the radiation dose to the surgeon and pati...

2007
Stephen F. Kry Michael Price David Followill Firas Mourtada Mohammad Salehpour

The commonly used thermoluminescent dosimeter TLD-100 (Harshaw Chemical Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high-energy therapies. As a result, TLD-100 measurements outside of the treatment field are suspect when high-energy radiation is used. Although alternatives such as TLD-700 do not respond to neutrons, specialty dos...

2015
Tatsiana A. Reynolds Patrick Higgins

The purpose of this study was to review application of a consistent correction method for the solid state detectors, such as thermoluminescent dosimeters (chips (cTLD) and powder (pTLD)), optically stimulated detectors (both closed (OSL) and open (eOSL)), and radiochromic (EBT2) and radiographic (EDR2) films. In addition, to compare measured surface dose using an extrapolation ionization chambe...

2017
Jaechan Park Sanggil Lee Chulyong Park Huisu Eom

BACKGROUND Interest in radiation-related health problems has been growing with the increase in the number of workers in radiation-related jobs. Although an occupational level of radiation exposure would not likely cause azoospermia, several studies have reported the relation between radiation exposure and azoospermia after accidental or therapeutic radiation exposure. We describe a case of azoo...

Journal: :The Quaternary Research (Daiyonki-Kenkyu) 1967

Journal: :iranian journal of medical physics 0
vahid lohrabian educational development center, ilam university of medical sciences, ilam, iran

introduction low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. dosimetric characteristics of a new irseed 125i brachytherapy source have been determined using the lif thermoluminescent dosimeter (tld) chips. materials and methods dose rate constant, radial dose function, and anisotropy function around the irseed 125i so...

2017
Zaid Alnewaini Eric Langer Philipp Schaber Matthias David Dominik Kretz Volker Steil Jürgen Hesser

OBJECTIVES Dosimetric control of staff exposure during interventional procedures under fluoroscopy is of high relevance. In this paper, a novel ray casting approximation of radiation transport is presented and the potential and limitation vs. a full Monte Carlo transport and dose measurements are discussed. METHOD The x-ray source of a Siemens Axiom Artix C-arm is modeled by a virtual source ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید