نتایج جستجو برای: thermoluminescence dosimeter

تعداد نتایج: 3015  

2013
Yuka Matsuzaki Keisuke Fujii Motoki Kumagai Ichiro Tsuruoka Shinichiro Mori

The capacity of 4DCT to quantify organ motion is beyond conventional 3DCT capability. Local control could be improved. However we are unaware of any reports of organ dose measurements for helical 4DCT imaging. We therefore quantified the radiation doses for helical 4DCT imaging. Organ and tissue dose was measured for thoracic and abdominal 4DCT in helical mode using an adult anthropomorphic pha...

2014
R. Chen V. Pagonis

Superlinear dose dependence of thermoluminescence (TL) and optically stimulated luminescence (OSL) has been reported for many materials. The theoretical explanation has been ascribed to competition of either traps or recombination centers, during the excitation stage or during the read-out phase. There has been an account in the literature on superlinearity of OSL associated with merely one tra...

Journal: :Clinical cancer research : an official journal of the American Association for Cancer Research 1999
M Sarfaraz B W Wessels

The purpose of this study was to validate an analytical expression for the absorbed-dose calculation from the spherical source of beta-emitting radionuclides and to apply it to micrometastases treated with radiolabeled monoclonal antibodies. The self-absorbed fractions from I-131 and P-32 uniform spherical sources were calculated using the analytical expression introduced by P. K. Leichner (J. ...

2017
Stephanie Keehan Ryan L. Smith Jeremy Millar Max Esser Michael L. Taylor Peta Lonski Tomas Kron Rick D. Franich

High energy radiotherapy can produce contaminant neutrons through the photonuclear effect. Patients receiving external beam radiation therapy to the pelvis may have high-density hip prostheses. Metallic materials such as those in hip prostheses, often have high cross-sections for neutron interaction. In this study, Thackray (UK) prosthetic hips have been irradiated by 18 MV radiotherapy beams t...

2015
Siti Nurasiah Binti Mat Nawi Nor Fadira Binti Wahib Nurul Najua Binti Zulkepely Yusoff Bin Mohd Amin Ung Ngie Min David Andrew Bradley Roslan Bin Md Nor Mohd Jamil Maah

Study has been undertaken of the thermoluminescence (TL) yield of various tailor-made flat cross-section 6 mol% Ge-doped silica fibers, differing only in respect of external dimensions. Key TL dosimetric characteristics have been investigated, including glow curves, dose response, sensitivity, fading and reproducibility. Using a (60)Co source, the samples were irradiated to doses within the ran...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2006
Chikako Kawabata Kichirou Koshida Mayumi Hayakawa Akira Chadani Hiroto Nakagawa Kimiya Noto Atsushi Fukuda Kousuke Matsubara Hiroji Iida

The applications of interventional radiology (IVR) increasingly are being used in clinical examinations, where they tend to extend examination time. In addition, the risk of occupational exposure necessarily is increasing with this technology. In this study, the dose distributions in a sliced acrylic-acid phantom involving the bore for each irradiation condition were measured using a thermolumi...

2014
Akmal Sabarudin Zakira Mustafa Khadijah Mohd Nassir Hamzaini Abdul Hamid Zhonghua Sun

This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the...

2017
Shih-Ming Hsu Chao-Hsiung Hung Yi-Jen Liao Hsiao-Mei Fu Jo-Ting Tsai Yung-Hui Huang David Y. C. Huang

CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotolumines...

Journal: :journal of biomedical physics and engineering 0
s zargan department of medical physics, babol university of medical sciences, babol, iran p ghafarian chronic respiratory diseases research center, national research institute of tuberculosis and lung diseases (nritld), shسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences)سازمان های دیگر: pet/ct and cyclotron center, masih daneshvari hospital, shahid beheshti university of medical sciences, tehran,

background: pet/ct imaging using [18f]-fdg is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. essential consideration must be taken for radiation staff due to high gamma radiation in pet/ct and cyclotron center. the aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in pet/ct an...

2013
T Juang J Newton S Das J Adamovics M Oldham

Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The deformable PRESAGE® dosimeter exhibited a linear dose response with a sensitivity of 0.0032 ΔOD/(Gy/cm). Comparison of an experimental dosimeter...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید