نتایج جستجو برای: tensile strength and young

تعداد نتایج: 16894436  

Journal: Geopersia 2015

This study investigates the correlations among the tensile strength, mineral composition, and textural features of twenty-ninesandstones from Kouzestan province. The regression analyses as well as artificial neural network (ANN) are also applied to evaluatethe correlations. The results of simple regression analyses show no correlation between mineralogical features and tensile strength.However,...

2002
Edson Santos F. Abe

The influence of laser processing parameters on mechanical properties and microstructure of pure titanium models made by selective laser melting is investigated. The density of the models can reach higher than 95% under proper conditions. Although the tensile strength test shows results comparable to the wrought material, the impact and torsional fatigue strengths are low because of porosity an...

2015
Dequan Shi Kaijiao Kang Guili Gao Zhijun Chen

By using the mechanical property tester, conductivity tester, DSC and optical microscope, the effects of the solid solution temperature, water temperature, transfer time and delay time of quenching on the mechanical properties and conductivity of 7475 alloy were investigated, respectively. The results showed that all properties are satisfied at the solid solution temperature of 460°C­480°C whil...

2015
Kyung-Joon Shin Kyu-Hyeon Jang Young-Cheol Choi Seong-Cheol Lee

In this paper, the flexural behavior of High-performance Fiber-Reinforced Cementitious Composite (HPFRCC) has been investigated, especially focusing on the localization of cracks, which significantly governs the flexural behavior of HPFRCC members. From four points bending tests with HPFRCC members, it was observed that almost evenly distributed cracks formed gradually, followed by a localized ...

2010

Increasing of strain rate during forming of semi products or products is one of the ways of production intensification. Therefore an attention is paid to the study of the influence of the strain rate on the material behaviour in the deformation process, but also on the methodology of evaluation of formability at increased strain rates (including impact) 1,2 . In general, it applies that increas...

2016
Geraint P. Williams Ben L. George Yoke R. Wong Xin-Yi Seah Heng-Pei Ang Mun Kitt A. Loke Shian Chao Tay Jod S. Mehta

The introduction of femtosecond laser assisted cataract surgery (FLACS) is a paradigm changing approach in cataract surgery, the most commonly performed surgical procedure. FLACS has the potential to optimize the creation of an anterior lens capsulotomy, a critical step in accessing the cataractous lens. The merits of using a laser instead of a manual approach include a potentially more circula...

2017
Xinge Zhang Liqun Li Yanbin Chen Zhaojun Yang Yanli Chen Xinjian Guo

In order to expand the application range of laser welding and improve weld quality, an extra pulse current was used to aid laser-welded 2219 aluminum alloy, and the effects of pulse current parameters on the weld microstructure and mechanical properties were investigated. The effect mechanisms of the pulse current interactions with the weld pool were evaluated. The results indicated that the co...

2014
Er Hong Song Ghafar Ali Sung Ho Yoo Qing Jiang Sung Oh Cho

Using density functional theory calculations, we have investigated the effects of biaxial tensile strain on the electronic and magnetic properties of partially hydrogenated graphene (PHG) structures. Our study demonstrates that PHG configuration with hexagon vacancies is more energetically favorable than several other types of PHG configurations. In addition, an appropriate biaxial tensile stra...

2014
Thomas Joffre Arttu Miettinen Erik L.G. Wernersson Per Isaksson E. Kristofer Gamstedt

Journal: :Annals of the Academy of Medicine, Singapore 1999
J W Chiu M H Goh

The tensile strengths of 12 commercially available brands of epidural catheters were assessed using an Instron material testing device. The mean values of the tensile strengths ranged from 1.89 to 3.74 kilogram force. The extent of catheter occlusion due to kinking was also studied using an in vitro apparatus designed to simulate drug delivery at various degrees of flow restriction. It was dete...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید