نتایج جستجو برای: spect ct

تعداد نتایج: 142504  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2007
Oliver Gaemperli Tiziano Schepis Ines Valenta Lars Husmann Hans Scheffel Victor Duerst Franz R Eberli Thomas F Luscher Hatem Alkadhi Philipp A Kaufmann

UNLABELLED Myocardial perfusion imaging with SPECT (SPECT-MPI) and 64-slice CT angiography (CTA) are both established techniques for the noninvasive evaluation of coronary artery disease (CAD). Three-dimensional (3D) SPECT/CT image fusion may offer an incremental diagnostic value by integrating both sets of information. We report our first clinical experiences with fused 3D SPECT/CT in CAD pati...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2005
Isis W Gayed E Edmund Kim William F Broussard Douglass Evans Jeffrey Lee Lyle D Broemeling Breanna B Ochoa Donna M Moxley William D Erwin Donald A Podoloff

UNLABELLED As SPECT/CT technology evolves, its applications and indications need to be evaluated clinically for more efficient and cost-effective use. This retrospective study evaluated the clinical value of simultaneously acquired (99m)Tc-sestamibi SPECT/CT versus conventional SPECT in diagnosing and locating parathyroid adenomas or hyperplasia in patients with primary hyperparathyroidism. M...

Journal: :The Journal of bone and joint surgery. British volume 2009
G I Pagenstert A Barg A G Leumann H Rasch J Müller-Brand B Hintermann V Valderrabano

The precise localisation of osteoarthritic changes is crucial for selective surgical treatment. Single photon-emission CT-CT (SPECT-CT) combines both morphological and biological information. We hypothesised that SPECT-CT increased the intra- and interobserver reliability to localise increased uptake compared with traditional evaluation of CT and bone scanning together. We evaluated 20 consecut...

Journal: :Journal of neurology, neurosurgery, and psychiatry 1997
A Mitchener D J Wyper J Patterson D M Hadley J T Wilson L C Scott M Jones G M Teasdale

Neuroimaging with single photon emission computed tomography (SPECT) using the cerebral blood flow tracer 99Tc(m)-HMPAO has been used to study acute functional alterations after head injury and residual abnormalities at six month follow up in 32 patients. Comparison has been made with anatomical abnormalities defined acutely with CT and on follow up with MRI. SPECT showed slightly more abnormal...

2015
Andele D de Zwart Frank JP Beeres Daphne DD Rietbergen Pieta Krijnen Inger B Schipper

BACKGROUND *Equal contributors.Planar bone scintigraphy (PBS) is often advocated for diagnosing occult scaphoid fractures. PBS is a sensitive diagnostic modality, but lacks specificity, which may result in over-diagnosis. PURPOSE To examine, in a pilot study, the potential additional value of single photon emission computed tomography (SPECT) combined with low dose computed tomography (CT) fo...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2010
Ravinder K Grewal R Michael Tuttle Joseph Fox Sunita Borkar Joanne F Chou Mithat Gonen H William Strauss Steven M Larson Heiko Schöder

UNLABELLED The objective of this study was to determine whether posttherapy (131)I SPECT/CT changed the need for additional cross-sectional imaging or modified the American Thyroid Association risk of recurrence classification. We performed planar imaging and SPECT/CT in a consecutive series of patients after (131)I therapy. METHODS Planar imaging and SPECT/CT were performed on 148 consecutiv...

Journal: :asia oceania journal of nuclear medicine and biology 0
elizabeth bailey departments of nuclear medicine, royal north shore hospital, australia dale bailey discipline of medical radiation sciences, university of sydney, australia stephen hunyor cardiac technology centre, north shore heart research group, kolling institute, australia leigh ladd charles sturt university, wagga wagga, australia george bautovich departments of nuclear medicine, royal north shore hospital, australia

background: pre-clinical investigation of stem cells for repairing damaged myocardium predominantly used rodents, however large animals have cardiac circulation closely resembling the human heart. the aim of this study was to evaluate whether spect/ct myocardial perfusion imaging (mpi) could be used for assessing sheep myocardium following an acute myocardial infarction (mi) and response to int...

Journal: :Clinical and Translational Imaging 2014

Journal: :The British Journal of Radiology 2017

2012
Kazuhiro Koshino Kazuhito Fukushima Masaji Fukumoto Kazunari Sasaki Tetsuaki Moriguchi Yuki Hori Tsutomu Zeniya Yoshihiro Nishimura Keisuke Kiso Hidehiro Iida

BACKGROUND Attenuation correction of a single photon emission computed tomography (SPECT) image is possible using computed tomography (CT)-based attenuation maps with hybrid SPECT/CT. CT attenuation maps acquired during breath holding can be misaligned with SPECT, generating artifacts in the reconstructed images. The purpose of this study was to investigate the effects of respiratory phase duri...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید