نتایج جستجو برای: scatter collimator factor

تعداد نتایج: 857363  

2013
Jessie Y. Huang David S. Followill Xin A. Wang Stephen F. Kry

Although treatment planning systems are generally thought to have poor accuracy for out-of-field dose calculations, little work has been done to quantify this dose calculation inaccuracy for modern treatment techniques, such as intensity-modulated radiation therapy (IMRT), or to understand the sources of this inaccuracy. The aim of this work is to evaluate the accuracy of out-of-field dose calc...

2010
Jina Chang Siyong Kim Doh‐Yun Jang Tae‐Suk Suh

A multiple-slit collimator (MSC) design was introduced for scatter reduction in cone-beam computed tomography (CBCT). Unlike most other collimators, the open and closed septa of the proposed MSC are placed in an equi-angular interval on a circular track of the central sagittal plane. Therefore, one gantry rotation provides only the half of necessary dataset and two gantry rotations are needed t...

2014
Robin de Nijs Vera Lagerburg Thomas L. Klausen Søren Holm

PURPOSE Patient-specific dosimetry of lutetium-177 ((177)Lu)-DOTATATE treatment in neuroendocrine tumours is important, because uptake differs across patients. Single photon emission computer tomography (SPECT)-based dosimetry requires a conversion factor between the obtained counts and the activity, which depends on the collimator type, the utilized energy windows and the applied scatter corre...

2011
Stephan Walrand Michel Hesse Georges Demonceau Stanislas Pauwels François Jamar

BACKGROUND The purpose of the study is to evaluate whether a pinhole collimator is better adapted to bremsstrahlung single photon emission computed tomography [SPECT] than parallel-hole collimators and in the affirmative, to evaluate whether pinhole bremsstrahlung SPECT, including a simple model of the scatter inside the patient, could provide a fast dosimetry assessment in liver selective inte...

2007
A. Miceli A. Flisch U. Sennhauser F. Casali M. Simon

An X-ray computed tomography (CT) model based on the GEANT4 Monte Carlo code was developed for simulation of a cone-beam CT system for industrial applications. The full simulation of the X-ray tube, object, and area detector was considered. The model was validated through comparison with experimental measurements of different test objects. There is good agreement between the simulated and measu...

Journal: :Physics in medicine and biology 2008
Sarah E Bohndiek Emily J Cook Costas D Arvanitis Alessandro Olivo Gary J Royle Andy T Clark Mark L Prydderch Renato Turchetta Robert D Speller

X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate i...

2014
Ivón Oramas Polo

Introduction: This paper presents a simulation for evaluation of the scattered radiation components produced in a gamma camera PARK using Monte Carlo code SIMIND. It simulates a whole body study with MDP (Methylene Diphosphonate) radiopharmaceutical based on Zubal anthropomorphic phantom, with some spinal lesions. Methods: The simulation was done by comparing 3 configurations for the detected p...

Journal: :iranian journal of radiation research 0
a. takavar department of medical physics, tehran university of medical sciences,tehran, iran gh. shamsipour m. sohrabi m. eftekhari

background: in myocardial perfusion spect imaging, images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. filters greatly affect quality of nuclear medicine images materials and methods: a phantom simulating heart left ventricle was built. about 1mci of 99mtc was injected into the phantom. images were taken from this phantom. some fi...

Journal: :iranian journal of nuclear medicine 0
mohsen hajizadeh saffar medical physics research center, school of medicine, mashhad university of medical sciences, mashhad, iran shabnam oloomi medical physics department, mashhad university of medical science, mashhad, iran peter knoll department of nuclear medicine, wilhelminenspital, vienna, austria hadi taleshi department of medical physics, faculty of medical sciences, tarbiat modares university, tehran, iran

introduction: scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. accurate estimation of scatter in projection data of spect is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. methods: the objective of this paper is to develop and validate a scatter correction technique t...

Journal: :Medical physics 2012
J Fan Q Xu L Wang L Jin J Li T Lin S Hayes T Tam C Ma

PURPOSE There are two collimation systems associated with the CyberKnife system, the fixed cone collimator and the Iris collimator. The Iris collimator is used more frequently because of its superior flexibility. However, sometimes treatments have to be canceled or postponed due to Iris collimator mechanical failures. The purpose of this study is to investigate the feasibility of switching coll...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید