نتایج جستجو برای: pvc membrane electrode

تعداد نتایج: 452869  

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2006
Mohammad Reza Yaftian Saeed Rayati Daryoush Emadi Dominique Matt

The preparation of a lead-selective electrode based on 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetrakis-(diphenylphosphinoylmethoxy)calix[4]arene (1) as an ionophore is reported. The plasticized PVC membrane containing 30% PVC, 57% ortho-nitrophenyloctylether (NPOE), 4% sodium tetraphenylborate (NaTPB) and 9% ionophore 1 was directly coated on a graphite electrode. It exhibits a nearly Nernstia...

ژورنال: سلامت و محیط زیست 2020

Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2004
Y M Issa S I M Zayed

A new oxymetazoline (OM) ion-selective PVC membrane electrode based on the ion associate of OM with phosphotungstic acid was prepared. The electrode exhibits a linear response with a mean calibration graph slope of 57.16 mV decade(-1) at 25 degrees C within the concentration range of 1.96 x 10(-5) - 1 x 10(-2) M OMCl. The change in the pH within the range of 1.0 - 9.4 did not affect the electro...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2005
Fahimeh Jalali Mohammad J Rajabi Gholamreza Bahrami Mojtaba Shamsipur

An iodide-miconazole ion-paired complex was used as a suitable ion-exchanger for the preparation of a plasticized-PVC membrane electrode. Among different solvent mediators tested, dioctylsebacate exhibited the proper response characteristics, including Nernstian slope of the calibration curve, fast response time and good reproducibility of the emf values. The electrode exhibits a Nernstian slop...

2015
Clifton Carey

The PVC membrane of an ion-selective electrode (ISE) sensitive to dibasic phosphate ions (HPO4-ISE) has not been optimized for maximum selectivity, sensitivity, and useable ISE lifetime and further work was necessary to improve its performance. Two areas of investigation are reported here: include the parameters for the lipophilicity of the plasticizer compound used and the amount of cyclic pol...

2009
Dong Wan Kim So Hyun Lee Junghwan Kim Jineun Kim Jong Keun Park Jae Sang Kim

A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium(II), [(dppe)PdX2, X = Cl (L), X = I (L)] as active sensor has been developed. The diiodopalladium complex, [(dppe)PdI2](L) displays an anti-Hofmeister selectivity sequence: SCN‒ > I‒ > ClO4‒ > Sal‒ > Br‒ > NO2‒ > HPO4‒ > AcO‒ > NO3‒ > H2PO4‒ > CO32‒. The electrode exhibits a Ne...

Journal: :analytical and bioanalytical chemistry research 2014
a. shokrollahi a. abbaspourb a. naghashian haghighia a. h. kianfar

a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m  with nernstian slope of 19.64 ± 0.15 mv decade-1...

2000
I. Poels A. van den Berg

Ž . Ž . An ion-selective field effect transistor ISFET was applied as a potentiometric detector in liquid chromatography LC for the Ž determination of organic acids. The ISFET was prepared by coating the gate insulator of the encapsulated transistor with a poly vinyl . Ž . chloride PVC matrix membrane containing methyltridodecylammoniumchloride, which enables the detection of organic anions. Th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید