نتایج جستجو برای: potentiometric method

تعداد نتایج: 1632258  

2016
Guangtao Zhao Jiawang Ding Han Yu Tanji Yin Wei Qin

A potentiometric aptasensing assay that couples the DNA nanostructure-modified magnetic beads with a solid-contact polycation-sensitive membrane electrode for the detection of Vibrio alginolyticus is herein described. The DNA nanostructure-modified magnetic beads are used for amplification of the potential response and elimination of the interfering effect from a complex sample matrix. The soli...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2001
J Yuan Y Hu L Nie S Yao

The construction and general performance characteristics of three piezoelectric quartz crystal sensors responsive to the pentoxyverine are described here. This kind of non-potentiometric sensing method is based on use of ion-pair complexes of the pentoxyverine cation with three counter anions, namely, tungstophosphate, tetraphenylborate and picrolonate. The complexes were embedded in a PVC matr...

2015
W. I. Zidan

The interest in nuclear safeguards is constantly growing, as more nuclear programs are being exposed all over the world. In this work, a simple, rapid and reliable method has been applied for the determination of uranium content in aqueous media based on using potentiometric sensor. The developed tool was found to be capable of verifying the operator declarations in a wide concentration range w...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Davood Nematollahi Ali Hamzehloei Mehdi Hesari Javad Rahimi

The electrochemical oxidation of iodide ion in the presence of 4-hydroxycoumarin (1) was studied using cyclic voltammetry and controlled-potential coulometry. The result indicates that the resulting iodine takes part in a halogenation reaction and reacts with 4-hydroxycoumarin (1). According to the obtained results, a new and simple coulometric titration method with potentiometric end-point det...

2014
Hardeep Kaur Sachin Kumar Neelam Verma

The aim of the present work was to study a simple colorimetric and potentiometric biosensor based on urease inhibition by Pb (II) ions for its estimation in milk samples. Urease immobilized on nylon membrane by hydrosol gel method was used as the biocomponent to demonstrate the metal effect on the enzyme activity using phenol red as the pH indicator. A lower limit detection of 38.6μm was achiev...

2009
R. Czoik A. Heintz E. John W. Marczak

The stability constants and enthalpies of formation of silver (I) complexes with histidine and imidazole were determined. Two types of complexes were found: AgL and AgL+2 . The second is much more stable that is evidenced by the higher stability constants and enthalpies of formation. For the two systems, the respective constants and enthalpies are very close one to another that suggests similar...

Journal: :Chemical & pharmaceutical bulletin 2004
Meeran Mohideen Abdul Kamal Nazer Abdul Rahman Shahul Hameed Patel Riyazuddin

A simple and rapid potentiometric method for the estimation of ascorbic acid in pharmaceutical dosage forms has been developed. The method is based on treating ascorbic acid with iodine and titration of the iodide produced equivalent to ascorbic acid with silver nitrate using Copper Based Mercury Film Electrode (CBMFE) as an indicator electrode. Interference study was carried to check possible ...

Journal: :Talanta 2010
Sara M Oliveira Teresa I M S Lopes Ildikó V Tóth António O S S Rangel

A multicommuted flow system with the propulsion device placed before detection is proposed for the determination of tartaric acid and free potassium in table and Port wines. A dialysis unit was introduced to increase sample dilution and minimize matrix interferences. The determination of tartaric acid was based on the spectrophotometric monitorization of the complex formed by the dialyzed analy...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید