نتایج جستجو برای: polymer gel dosimeter nipam
تعداد نتایج: 195981 فیلتر نتایج به سال:
Background: In this study a series of basic dosimetric properties of a low-density (LD) gel dosimeter are investigated. The dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. Materials and Methods: The LD gel was made by mixing the polymer gel with expanded polystyrene spheres. Energy dependence was studied...
The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...
Raman spectroscopy are used to characterize the chemical changes in normoxic polyhydroxyethylacrylate gel dosimeter (PHEA) induced by radiation. Irradiations in the low dose region are performed and the polymerizations of PHEA gels are monitored by the observing the changes of Raman shift intensity of the carbon covalent bond of PHEA originated from both monomer and the cross-linker. The variat...
Radiation sensitive polymer gels are among the most promising three-dimensional dose verification tools developed to date. Polymer gel dosimeter known by the acronym MAGIC has been tested for evaluation of its use in boron neutron capture (BNCT) dosimetry. We irradiated a large (diameter 10 cm, length 20 cm) cylindrical gel phantom in the epithermal neutron beam of the Finnish BNCT facility at ...
Modern radiotherapy techniques try to deliver the radiation dose by steep gradient. Protocols for these complex treatment delivery techniques are important and extremely sensitive to errors in treatment delivery. To minimize such errors, 3D dosimeters were developed as a relative method for improving dose monitoring and delivery. The aim of this study is to analyze the capability and drawbacks ...
PURPOSE To obtain and assess the accuracy of 3D dose distributions and LET maps from a passively-scattered proton beam through the use of LET-dependent and LET-independent polymer gel formulations. METHODS Dose measurements were performed with BANG3-Pro2 (MGS Research, Inc, Madison, CT) polymer gel dosimeters. The dosimeters were mixed from kits and were poured into 14.5 cm high by 15 cm diam...
introduction: different dosimetric modalities (e.g., ionization chambers, semiconductors, tlds, radiographic films) often have some problems determining isodose curves and percentage depth doses in high dose gradient regions. research has been ongoing to develop portable high resolution dosimetry devices with accurate absolute dosimetry capabilities and easy data analysis. the ‘presage’ dosimet...
1. Introduction Magnetic resonance imaging (MRI) can non-invasively and non-destructively probe the magnetization of hydrogen atoms on water molecules in large objects with a high spatial resolution, and in three dimensions. This unique combination of properties is exploited in polymer gel dosimetry since original gel dosimeters, in which viscosity changes were measured and related to the absor...
introduction: despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. in the current work, the feasibility of using a normoxic polymer gel dosimeter named magica has been investigated for use in our clinical brachytherapy applic...