نتایج جستجو برای: plane parallel chamber
تعداد نتایج: 374637 فیلتر نتایج به سال:
PURPOSE To demonstrate that high-resolution biometry is possible in mouse eyes in vivo, using real-time OCT with focal plane advancement by a stepper motor. METHODS OCT images of eyes were taken from nine 29-day-old C57BL/6 mice(18 eyes) on two consecutive days. A custom-built real-time OCT instrument with a stepper motor was used to advance the focal plane from the corneal apex to the retina...
We demonstrate a method to determine the Brownian motion and the diffusion coefficient of a nanoparticle in water in a plane that is parallel to a solid boundary and as function of the distance normal to that boundary by using an optical tweezers instrument. A solution of 190 nm-diameter fluorescent polystyrene nanoparticles in de-ionized (DI) water is introduced in a micro-chamber built from t...
Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map t...
PURPOSE This study investigates a large-area plane-parallel ionization chamber (LAC) for measurements of dose-area product in water (DAPw ) in megavoltage (MV) photon fields. METHODS Uniformity of electrode separation of the LAC (PTW34070 Bragg Peak Chamber, sensitive volume diameter: 8.16 cm) was measured using high-resolution microCT. Signal dependence on angle α of beam incidence for squar...
Current dosimetry protocols recommend the use of plane-parallel ionization chambers for the dosimetry of clinical electron beams. The necessary perturbation corrections p(wall) and p(cav) are assumed to be unity, independent of the depth of measurement and the energy of the primary electrons. To verify these assumptions detailed Monte Carlo studies of a Roos chamber in clinical electron beams w...
Several successful Hall thruster plume studies have been conducted at the University of Michigan using a 45degree parallel-plate electrostatic energy analyzer mounted externally to the vacuum chamber. This requires the thruster to be in close proximity to the chamber walls potentially resulting in some set-up induced inaccuracies of the ion voltage distributions. A new design has been developed...
In this paper, the analytical solution of an electric and Volterra edge dislocation in a functionally graded piezoelectric (FGP) medium is obtained by means of complex Fourier transform. The system is subjected to in-plane mechanical and electrical loading. The material properties of the medium vary exponentially with coordinating parallel to the crack. In this study, the rate of the gradual ch...
The refraction phenomenon at the interface of an ordinary material and a lossy metamaterial has been investigated. For oblique incidence on the lossy metamaterial, the planes of constant amplitude of the refracted wave are parallel to the interface and the plane of constant phases make a real angle with the interface (real refraction angle). The real refraction angle and hence, the real refract...
Based on classical plate theory, standard and spectral finite element methods are extended for vibration and dynamic stability of axially moving thin plates subjected to in-plane forces. The formulation of the standard method earned through Hamilton’s principle is independent of element type. But for solving numerical examples, an isoparametric quadrilateral element is developed using Lagrange ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید