نتایج جستجو برای: pixelated collimator

تعداد نتایج: 3420  

2014
M. Kolstein G. Ariño M. Chmeissani G. De Lorenzo

The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated semiconductor technology for nuclear medicine applications to achieve an improved image reconstruction without efficiency loss. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (o...

Journal: :Journal of Nuclear Medicine Technology 2021

The aim of this study was to analyze the interobserver agreement visual and quantitative assessment cardiac 123I-metaiodobenzylguanidine scintigraphy. Methods: Planar images were acquired using a low-energy collimator. heart-to-mediastinum (HM) ratio adjusted for use collimator, published formula. Interpretation undertaken both visually after addition HM ratios. Image findings...

Journal: :Japanese Journal of Radiological Technology 1972

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

Journal: :Silampari Jurnal Pendidikan Ilmu Fisika 2022

A collimator simulator which is an accessory in radiology equipment, has been made. This was created as a learning medium to complete students' understanding studying x-rays part of electromagnetic waves. The research divided into two stages, namely the manufacture simulators and implementation teaching materials. equipped with blades that are used limit radiation field area. In this study, lam...

2002
Toru GOTO Yu GONG

The problems caused by miniaturization of the goniometer are discussed from the viewpoint of the stress error caused by mis-setting of the specimen and misalignment of the collimator and detector for the Q assembly X-ray stress analyzer using a position sensitive detector. The stress errors were calculated using a model and a simulation method. It was found that they tend to increase with the d...

2001
James E. Baciak

Thick mercuric iodide (HgI 2 ) detectors are investigated as potential room temperature gamma-ray spectrometers. By using pixelated anodes the induced charge on the electrode is dependent mainly on electron movement and is almost independent of the depth of interaction. Moreover, by reading out the planar cathode signal simultaneously, the depth of interaction can be determined and any effects ...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 1983
A Brahme J Eenmaa S Lindbäck A Montelius P Wootton

The dose distributional properties of a p(50) Be neutron beam using a continuously variable multi-leaf collimator are presented and compared with a 6 MV photon beam. The differences in physical dose delivery between these two radiation modalities are generally insignificant for radiation therapy, and stringent comparisons of neutron and photon treatments should therefore be possible. The flexib...

2010
V.W.Y Choi E.H.W. Yum K. N. Yu

In the present paper, we propose a method to fabricate a ‘‘micro-collimator’’ with a thickness of 15mm. A commercially available PADC film with a thickness of 100mm was first chemically etched with NaOH/ethanol solution to obtain a thin PADC film. This thin PADC film was then irradiated by 5MeV a particles through a ‘‘macro-collimator’’ with a thickness of 5mm and a hole diameter of 1mm. This P...

Journal: :Physics in medicine and biology 1998
G L Zeng G T Gullberg

In single photon emission computed tomography (SPECT), a varying-focal-length cone-beam collimator can be used to reduce the truncation problem and to maintain sensitivity when imaging the organ of interest. The collimator is constructed so that the collimator holes focus to a circular symmetric, spatially varying, focal point function. The focal length increases radially from the shortest foca...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید