نتایج جستجو برای: perchlorate selective electrode

تعداد نتایج: 263113  

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical & theoretical chemistry 2012
r. aminameli m. h. fekri h. shafie m. darvishpour h. khanmohammadi

a pvc membrane fe(iii) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.the electrode exhibits a good potentiometric response for fe(iii) over a wideconcentration range 1.0×10-4 to 1.0×10-1m with a slope 19.4±0.5 mv/decade a and a working phrange of 6.5-9.0. it has a fast response time ≤30s.the best performance was observed with themembrance having the 30....

Journal: :journal of physical & theoretical chemistry 2004
h. aghaie m. giahi1 giahi m. aghaei m. arvand3

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n&apos;1,n&apos;2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

Journal: :journal of physical and theoretical chemistry 0
m. aghaie - m. h. fekri - m. giahi - e. baghdar - s. farhadi -

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :Environmental science & technology 2007
Mamadou S Diallo Kwesi Falconer James H Johnson William A Goddard

Perchlorate (ClO4-) has emerged as a major groundwater and surface water contaminant in the United States. Ion exchange (IX) is the most widely used technology for treating water containing lower concentrations of perchlorate (<100 ppb). However, a major drawback of IX is the need for frequent regeneration or disposal of the perchlorate-laden resins. As a first step toward the development of hi...

Journal: :Talanta 2000
M L Magnuson E T Urbansky C A Kelty

Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed ...

2011
Z. Wang B.P.-Y. Lau B. Tague M. Sparling D. Forsyth

A sensitive and selective isotope dilution ion chromatography/tandem mass spectrometry (ID IC-MS/MS) method was developed and validated for the determination of perchlorate in infant formula. The perchlorate was extracted from infant formula by using 20 ml of methanol and 5 ml of 1% acetic acid. All samples were spiked with (18)O(4) isotope-labelled perchlorate internal standard prior to extrac...

Journal: :nanochemistry research 0
abbas afkhami faculty of chemistry, bu-ali sina university, hamedan, iran mahdi moradi faculty of chemistry, bu-ali sina university, hamedan, iran atousa bahiraei faculty of chemistry, bu-ali sina university, hamedan, iran tayyebeh madrakian faculty of chemistry, bu-ali sina university, hamedan, iran

in the present study, a new chemically modified carbon paste electrode (cpe) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of mo (vi) using differential pulse voltammetry. the electrode was prepared using magnetic nickel zinc ferrite nanocomposite (ni0.5zn0.5fe2o4), as the modifier in cpe (ni0.5zn0.5fe2o4/cpe). mo (vi) was determined after preconcentr...

Journal: :Clinical chemistry 1973
G M Schmid G W Bolger

Gold is determined in aqueous gold-containing drug solutions, 8 X 108 to 1 X 10 mol/liter, and in such drugs in serum, 2 X 106 to 1 X 10 mol/ liter, by electrodeposition onto a carbon paste electrode at -0.3 V vs. a saturated calomel electrode and subsequent stripping at constant current. Aqueous solutions are prepared for electrodeposition with a ceric perchlorate-hydrogen peroxide treatment. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید