The manual process of manufacturing the welding electrode takes more time and work. It also occupies more space for the control panel with the installation of PLC in the welding electrode manufacturing control panel the size of the panel is reduced to the great extent. It has reduced the cost of the panel and has increased the rate of the production. Here the entire process of electrode manufac...
BACKGROUND Despite the increasing popularity of wrist-cuff blood pressure (BP) devices, their accuracy has not been established and international guidelines do not support their use. Because arm position influences BP measurement, it is possible that conflicting reports on wrist-cuff device accuracy reflects diverse arm positions. METHOD This study compared BP measured by two oscillometric de...
A study was undertaken to assess the accuracy of the Omron HEM-907 blood pressure measuring device for use in community studies. A modified version of the British Hypertension Society (BHS) and American Association for the Advancement Medical Instrumentation (AAMI) protocol for measuring the accuracy of a blood pressure measuring device was used. A total of 104 subjects were recruited from two ...
BACKGROUND Masked hypertension (MHT), defined as normal blood pressure (BP) at office associated with high BP at home, has been shown to be associated with an increased risk of vascular events. However, MHT is poorly known in the elderly, although this age segment is at high risk of hypertension-related vascular events. Our objectives were to assess frequency and determinants of MHT in the elde...
Pedometers are a popular way for people to track if they have reached the recommended 10,000 daily steps. Therefore, the purpose of this study was to determine the accuracy of four brands of pedometers at measuring steps, and to determine if a relationship exists between pedometer cost and accuracy. The hypothesis was that the more expensive brands of pedometers (the Fitbit Charge™ and Omron HJ...
OBJECTIVE To evaluate the effectiveness of self-measurement of blood pressure (SMBP) in controlling hypertension. DESIGN Randomized, controlled, pragmatic, open study. The unit of randomization was the basic health care unit (BCU), consisting of 1 physician and 1 nurse. All BCUs were randomized to the control group (usual clinical practice, n=94) or to the intervention group (n=86). SETTING...