INTRODUCTION Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasia. The aim of this work was to find out if there is a statistically significant correlation betwee...
INTRODUCTION The Goldmann applanation tonometer readings were noted to be markedly reduced after Lasik surgery using a thin flap technique which is widely used nowadays, to correct a wide range of myopia and astigmatism. The Ocular Response Analyzer (ORA) is considered one of the important tools for refinement of Intraocular Pressure (IOP) measurements. The aim of this study is to evaluate and ...
BACKGROUND To evaluate the relationships between Reichert Ocular Response Analyzer (ORA) parameters corneal hysteresis (CH) and corneal response factor (CRF) and ocular dimensions, age and intraocular pressure. METHODS Two hundred and twelve eyes of 212 participants with no ocular pathology had CH and CRF measured with the ORA. Intraocular pressure (IOP) was measured with the Dynamic Contour ...
Corneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s with the Humphrey Field Analyzer. VF progression was...
Methods: Ten eyes of 10 patients aged 26.5 6 5.7 (mean 6 SD) years with progressive keratoconus were treated with UV-A– riboflavin CXL and assessed with the Ocular Response Analyzer (ORA) that measured corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal compensated intraocular pressure (IOPcc). Intraocular pressure was also meas...
PURPOSE Pressure curves obtained from Ocular Response Analyzer (ORA) differ for the same patient in form and height. In some cases measurements on the subject show significant differences between recorded pressure curves. The purpose of the paper is to examine if the differences result from the corneal properties or from the device operation. METHODS Examination of air pressure curves was car...