نتایج جستجو برای: normoxic polymer gel

تعداد نتایج: 197226  

2017
Rahim Sabbaghizadeh Roslinda Shamsudin Najmeh Deyhimihaghighi Arman Sedghi

In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produ...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi,

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2007
mohammad simjoo mohsen vafaie sefti ahmad dadvand koohi reza hasheminasab valiahmad sajadian

in this paper, polyacrylamide/chromium acetate gel polymer system was prepared as water shut-off system to control water production in one of the iranian oil reservoirs condition. effect of various parameters such as temperature (90 °c) and water formation from view point of salinity and divalent cations, was evaluated on the gelation kinetic and gel strength using bottle testing method. the re...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

Journal: :iranian journal of medical physics 0
hamid reza sadoughi m.sc. student of medical physics, medical physics dept., tehran university of medical sciences, tehran, iran mahmood allahverdi associate professor, medical physics dept., tehran university of medical sciences, and radiotherapy physics department of cancer institute, tehran, iran hasan nedaei assistant professor, radiotherapy physics dept., cancer institute, tehran, iran ramin jaberi radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran mahbod esfahani radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran alireza shirazi associated professor, medical physics dept., tehran university of medical sciences, tehran, iran

introduction: multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. in this work, we investigated mr-based magic gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. materials and methods: a heterogeneous slab phantom including bones was made....

K. Adinehvand, M.H. Zahmatkesh, M.R Aghamiri, S. Bagheri, Sh. Akhlaghpour,

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید