نتایج جستجو برای: mm wave detector

تعداد نتایج: 462640  

2008
A. N. Ramaprakash Ranjan Gupta A. K. Sen

| Taking advantage of the advances in array detector technology, an imaging polarimeter (IMPOL) has been constructed for measuring linear polarization in the wavelength band from 400-800 nm. It makes use of a Wollaston prism as the analyser to measure simultaneously the two orthogonal polarization components that deene a Stoke's parameter. An achromatic half-wave plate is used to rotate the pla...

2006
Amber L. Stuver Lee Samuel Finn

A number of different methods have been proposed to identify unanticipated burst sources of gravitational waves in data arising from LIGO and other gravitational wave detectors. When confronted with such a wide variety of methods one is moved to ask if they are all necessary: i.e., given detector data that is assumed to have no gravitational wave signals present, do they generally identify the ...

حسین آفریده, , رحیم کوهی فایق, , غلامرضا اصلانی, , غلامرضا اطاعتی, , فریدون عباسی دوانی, ,

  In this project the neutron spectra from the reaction of deutron on beryllium muclei is measured. The energies of deuterons were 7, 10, 13 and 15 MeV, and these measurements are performed at 10, 30 and 50 degrees relative to the beam of deutrons. The detector used is 76 by 76 mm right circular cylender of NE-213 liquid scintillator. The zero crossing technique is used for gamma discriminatin....

2003

Dual recycling is the combination of signal recycling and power recycling; both optical techniques improve the shot-noise-limited sensitivity of interferometric gravitational-wave detectors. In addition, signal recycling can reduce the loss of light power due to imperfect interference and allows, in principle, to beat the standard quantum limit. The interferometric gravitational-wave detector G...

Journal: :Classical and Quantum Gravity 2002

Journal: :Journal of cardiovascular computed tomography 2013
Jochen von Spiczak Fabian Morsbach Sebastian Winklhofer Thomas Frauenfelder Sebastian Leschka Thomas Flohr David Maintz Harald Seifarth Alexander C Bunck Paul Stolzmann Hatem Alkadhi

BACKGROUND Despite continuous improvements in CT technology, accurate stent lumen delineation remains challenging. PURPOSE The aim was to evaluate the quality of coronary stent lumen delineation with CT using a detector with integrated electronics. METHODS Twelve coronary stents placed in plastic tubes and filled with contrast agent (CT number 250 HU) were imaged with either a 128-section d...

Journal: :Journal of Computational Vision and Imaging Systems 2018

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید