نتایج جستجو برای: metal on polyethylene
تعداد نتایج: 8529332 فیلتر نتایج به سال:
This study assessed the results of 90 one-component revisions for failed hip resurfacing due to adverse reaction to metal wear debris (76 acetabular, 14 femoral). Patients with a femoral head size 40-45 mm (n=33) received a two-piece titanium meshed shell with a cross-linked polyethylene liner and patients with femoral head size 46-54 mm (n=43) received metal-on-metal components. Patients with ...
Choice of implant combinations in total hip replacement: systematic review and network meta-analysis
Objective To compare the survival of different implant combinations for primary total hip replacement (THR). Design Systematic review and network meta-analysis. Data sources Medline, Embase, The Cochrane Library, ClinicalTrials.gov, WHO International Clinical Trials Registry Platform, and the EU Clinical Trials Register.Review methods Published randomised controlled trials comparing different i...
We studied the quality of fixation of the tibial component using radiostereometric analysis (RSA) in 40 patients who had undergone a cemented Freeman-Samuelson total knee arthroplasty. They were prospectively randomised to either a stemmed metal-backed (MB) or non-stemmed all-polyethylene (AP) tibial component. The articulating geometry of the implants was identical, as was the operative techni...
BACKGROUND AND PURPOSE The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were p...
OBJECTIVE To describe and clinically and radiographically compare patients who underwent total knee arthroplasty (TKA) with all-polyethylene (ALP) and metal-backed (MTB) tibial implants. METHODS Patients who underwent TKA between January 1988 and December 2004 were grouped according to the type of implant received: all-polyethylene or metal-backed. Sixty patients came for evaluations, totalin...
Total hip arthroplasty with metal-on-polyethylene implants and metal-on-metal articulations have been an area of recent interest. This article describes a patient with a persistent small soft tissue mass on the anterior groin following total hip arthroplasty with negative findings on infection workup, including blood work and aspiration. Subsequent biopsy findings were consistent with organizin...
The role of modular tibial implants in total knee replacement is not fully defined. We performed a prospective randomised controlled clinical trial using radiostereophotogrammetric analysis to compare the performance of an all-polyethylene tibia with a metal-backed cruciate-retaining condylar design, PFC-Sigma total knee replacement for up to 24 months. There were 51 patients who were randomise...
The development of two-dimensional (2D) materials has been experiencing a renaissance since the adventure of graphene. Layered transition metal dichalcogenides (TMDs) are now playing increasingly important roles in both fundamental studies and technological applications due to their wide range of material properties from semiconductors, metals to superconductors. However, a material with fixed ...
With the continuous exploration of 2D transition metal dichalcogenides (TMDs), novel high-performance devices based on the remarkable electronic and optoelectronic natures of 2D TMDs are increasingly emerging. As fresh blood of 2D TMD family, anisotropic MTe2 and ReX2 (M = Mo, W, and X = S, Se) have drawn increasing attention owing to their low-symmetry structures and charming properties of mec...
INTRODUCTION: Metal on metal bearings exhibit a biphasic wear mode, starting with a ‘bedding-in’ period of higher wear followed by a lower steady wear which may have favorable total wear [1]. However, there are cases of ‘run-away’ wear resulting in significantly higher total wear for the metal on metal bearing [2,3]. Many of these ‘run-away’ cases need to be revised which brings up the followin...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید