This study applies CT-based structural rigidity analysis (CTRA) to assess failure torque of rat femurs with simulated lytic defects at different locations (proximal and distal femur) and diameters (25% and 50% of the cross-section at the site), and compared the results to those obtained from mechanical testing. Moreover, it aims to compare the correlation coefficients between CTRA-based failure...
The aim of the study was to evaluate mechanical behavior of implants inserted in three substrates, by measuring the pullout strength and the relative stiffness. 32 implants (Master Porous-Conexao, cylindrical, external hexagon, and surface treatment) were divided into 4 groups (n = 8): pig rib bone, polyurethane Synbone, polyurethane Nacional 40 PCF, and pinus wood. Implants were installed with...
Locomotor adaptation in humans is not well understood. To provide insight into the neural reorganization that occurs following a significant disruption to one's learned neuromuscular map relating a given motor command to its resulting muscular action, we tied the mechanical action of a robotic exoskeleton to the electromyography (EMG) profile of the soleus muscle during walking. The powered exo...
Purpose – This paper introduces a new manipulator structure to configure power-assist devices in order to protect operators from musculoskeletal disorders. The mechanical structure and the control system are presented, along with their main features. Design/methodology/approach – The new structure is designed under the criterion of minimizing the torques required for handling payloads of up to ...
Magnetic microactuation systems of torsion silicon cantilever is described. Devices are constructed in a batch fabrication process which combines electroplating with conventional photolithography , materials, and equipment. The magnetic transducers are applied to generation of motion in micromechanical structures such as cantilever, beam, membrane. Microelectromechanical systems (MEMS) with mag...
Piezo ceramics are the key to significant improvements over conventional electromagnetic motors for the execution of precise movements with medical equipment. The latest generation piezo ceramic motors and actuators are more compact, require lower voltage, deliver higher torque, have shorter response time, generate less heat, and are nonmagnetic and vacuum compatible compared to EM motors. With...
Passive haptic displays have several advantages when compared to active devices. Safety elements associated with active haptic displays may make them undesirable for certain applications. One method of actuation for passive haptic robots is through the use of brakes and clutches. Traditionally, friction brakes have undesirable behavior, such as stiction and delay in response time due to mechani...
Successful endodontic treatment mainly relies on preserving the original anatomy of the root canal while avoiding instrument fractures and iatrogenic preparation errors, such as loss of working length, zipping, or ledging [1,2]. In most cases, rotary instrumentation has proved a valuable advancement for meeting these parameters. Unlike stainless steel files, nickel-titanium instruments have suf...
Graphene annulus possesses special wrinkling phenomenon with wide range of potential applications. Using molecular dynamics simulation, this study concerns the effect of boundary on the mechanical properties of circular and elliptical graphene annuli under circular shearing at inner edge. Both the wrinkle characteristic and torque capacity of annular graphene can be effectively tuned by outer b...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید