In this work, we outline an automated method for the extraction and quantification of material parameters characterizing collagen fibre orientations from two-dimensional images. Morphological collagen data among different length scales were obtained by combining the established methods of Fourier power spectrum analysis, wedge filtering and progressive regions of interest splitting. Our propose...
We have evaluated the performance of strain-chirped fiber Bragg grating (FBG) based tunable dispersion compensator in a 40 Gb/s transmission link. In our proposed compensator, the value of dispersion could be changed from -353 ps/nm to -962 ps/nm by adjusting the rotation angle of the metal beam on which the FBG was mounted. In order to evaluate the effect of ripples in reflectivity and variati...
Manipulation of dispersion curve for enhancing surface plasmon resonance (SPR) detection is proposed. Based on strong correlation between slope of dispersion curve and SPR angle shift, it is confirmed that dispersion curve characteristics can be employed as an analysis tool to evaluate SPR sensor performance and to predict anomalous plasmonic behaviors. Complicated resonance shift in SPR angle,...
The impact between particles or agglomerates and a device wall is considered as an important mechanism controlling the dispersion of active pharmaceutical ingredient (API) particles in dry powder inhalers (DPIs). In order to characterise the influencing factors and better understand the impact induced dispersion process for carrier-based DPIs, the impact behaviour between an agglomerate and a w...
results the maximum si was obtained at the highest applied flip angle (45°). the linear relationship between si and nanoparticle concentration was seen up to 112.21 and 98.83 μmol fe/l for the short (10°) and the long (45°) flip angles, respectively (r2 = 0.95). these values were reduced up to 48.54 and 42.73 μmol fe/l for these flip angles with r2 of 0.99. conclusions the maximum si will be in...
P wave parameters measured by 12-lead electrocardiogram (ECG) are commonly used as a noninvasive tool to evaluate left atrial enlargement. This study was designed to assess whether P wave parameters were associated with renal outcomes in chronic kidney disease (CKD) patients. This longitudinal study enrolled 439 patients with CKD stages 3-5. Renal end points were defined as the commencement of ...
In this paper, the optical properties of a semi-infinite medium composed of graphen-based hyperbolic meta-materials with the optical axis were tilted with respect to its boundary with air, by using the Maxwell equations; then the homogeneous effective medium approximation method was studied. The results showed that the orientation of the structure layers (geometric induced anisotropy) affec...
The object of this research is the investigation of carbon nanotube (CNT) distribution effect on electrical conductivity of polymer-CNT composite as dosimetry response of this system. Thus, electrical conductivity of this composite was simulated for aligned, homogenous, and agglomerated distributions in 2D, and 3D situations. The results of simulation were compared and validated by experimental...