The radiological properties of nanocomposite Fricke gel (NC-FG) dosimeters prepared with different concentrations of nano-clay, perchloric acid and ferrous ions in deaerated conditions were investigated under carbon and argon ion beam irradiation covering a linear-energy-transfer (LET) range of 10 to 3000 eV/nm. We found that NC-FG exhibits radiological properties distinct from those of convent...
The paper describes dose response and signal fading of Al-gate p-channel (metal oxide semiconductor field effect transistors) MOSFETs in the range of gamma radiation doses used in radiation therapy. MOSFETs with thicknesses of the gate oxide layer of 1 μm and 400 nm were used. The response was characterized by the threshold voltage shift and was studied as a function of the absorbed dose and ti...
Low intensity beams are generated with a 18 MeV Sband electron linear accelerator at Osaka Prefecture University. The minimum charge of electrons in a pulsed beam is about several aC. Study has been made to establish the methods for measuring the intensity and the spatial profile of the beam at electron charges of a beam in aC to pC regions. In pC region a beam monitor using a charge-sensitive ...
The Brazilian legislation has only established diagnostic reference levels (DRLs) in terms of Multiple Scan Average Dose (MSAD) as a quality control parameter for computed tomography (CT) scanners. Compliance with DRLs can be verified by measuring the Computed Tomography Kerma Index (Ca,100) with a pencil ionization chamber or by obtaining the kerma distribution in CT scans with radiochromic fi...
background: 7-lif: mg,cu,p (gr-207a) is one kind of thermo-luminescent dosimeters (tld) which can be used in diagnostic radiology and radiotherapy applications. because of having suitable properties such as good sensitivity, small size and being tissue equivalent, thermo-luminescent dosimetry has been one of the most important techniques in medicine over many years. choosing a correct energy fo...
The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivit...
PURPOSE To evaluate the effects of overlapping dose volumes for varying field arrangements in two formulations of PRESAGE®: one intended for, and irradiated with, proton beams and the other photon beams. METHODS For each treatment modality (photon, proton), three overlapping field setups were performed. These included a stationary dosimeter irradiated over six fractions, a dosimeter shifted l...
The innovation of adding a gel matrix to the traditional Fricke dosimeter to stabilize geometric information established the field of gel dosimetry for radiation therapy. A discussion of Fricke gels provides an overview of the issues that determine the dose response of all gel dosimeters in general. In this paper we review some of the features of Fricke systems to illustrate these issues and, i...
Six national standards for absorbed dose to water in Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 5 to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The standards are in agreement at the level of around 0.5%, which is significantly smaller than the stated standard uncertainties. r 2006 Elsevie...
This review paper presents an overview of individual monitoring, as well as the national dose register and dose record management of radiation workers in China. Progress has recently been made on the individual monitoring of radiation workers. A critical analysis of current status and problems in individual monitoring is also presented and necessary future research on individual monitoring, suc...