نتایج جستجو برای: linear attenuation coefficient

تعداد نتایج: 671039  

2003
T. P. Lerch S. P. Neal

The ultrasonic attenuation coefficient of a fluid or solid material is an acoustic parameter routinely estimated in nondestructive evaluation (NDE) and biological tissue characterization. In this paper, a new measurement and analysis technique for estimating the attenuation coefficient as a function of frequency for a fluid or solid is described. This broadband technique combines two establishe...

A. Vyas P. Kumar R. Ravanfar Haghighi S. Chatterjee,

Introduction: The photoelectric attenuation coefficient of substances is known to depend upon the energy E of the photon and the effective atomic number of substances (Zeff) as (Zeffx/Ey).  No definitive values about these indices x, y are given in the literature. The index x is said to lie between, 3.0 and 4.0, while for ‘y’ different values have been assigned, between 3.0 and 4.0. Method...

Journal: :Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine 2002
Yasutomo Fujii Nobuyuki Taniguchi Kouichi Itoh Kouichiro Shigeta Yi Wang Jing-Wen Tsao Kenji Kumasaki Takashi Itoh

OBJECTIVE To assess the feasibility of a new method of measuring the attenuation coefficient in the liver, which offers less variability of results than the conventional method. METHODS The attenuation coefficient was evaluated on the basis of the following equation with sound field correction: [log(M0 (z)) - tau(z)]. In our system, the attenuation coefficient was also evaluated by the spectr...

A. Shams, H. Shahbazian, M.A. Behrooz, M.J. Tahmasebi Birgani,

Background: Attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. So, its exact measurement or calculation is very important. The aim of this study was to evaluate the μ in different points in the water phantom anal...

Introduction: The present study aimed to evaluate the impact of PbO nano and micro-sized fillers on ordinary and heavy concretes for different photon energies. Material and Methods: The MCNPX Monte Carlo code (version 2.6.0) was used for all simulations in the present study. A model of narrow-beam geometry was validated and utilized to calcul...

2012
Jin-Hyeok Kim Won-Chul Choi Seung-Ri Jin Dong-Jo Park

In this paper, an analysis of a target location estimation system using the best linear unbiased estimator (BLUE) for high performance radar systems is presented. In synthetic environments, we are here concerned with three key elements of radar system modeling, which makes radar systems operates accurately in strategic situation in virtual ground. Radar Cross Section (RCS) modeling is used to d...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri department of medical physics, shahid sadoghi university of medical sciences, yazd, iran t. bayat department of medical physics, centre for education and training, zanjan, iran m.h. dashti r department of physiology, shahid sadoghi university of medical sciences, yazd, iran j. ghisari department of physics, yazd university, yazd, iran n. abdoli department of architecture, yazd university, yazd, iran

abstract  introduction: recently uses of medium and high energy x-rays has been increased in iran and radiotherapy centers along with a variety of accelerators have been installed in some provinces. in the other hand there is no sufficient skill in designing and making radiotherapy treatment rooms. this study was conducted to evaluate the efficacy of different mixtures of barite concrete for sh...

2007
Cangli Liu Thomas J. Ahrens

The velocity and attenuation of ultrasonic stress waves in gabbroic rock samples (San Marcos, California) subjected to shock loading in the 2 GPa range were studied. From P wave velocity measurements we determined the damage parameter Dp and crack density e of the samples and related these to the attenuation coefficient (quality factor) under dynamic strains of 2 x 10 -? and at a frequency of 2...

2015
Yunsong Zhao Mengfei Li Li Zeng

In this paper, we propose an iterative beam hardening correction method that is applicable for the case with multiple materials. By assuming that the materials composing scanned object are known and that they are distinguishable by their linear attenuation coefficients at some given energy, the beam hardening correction problem is converted into a nonlinear system problem, which is then solved ...

2012

A of seismic waves is sensitive to the physical properties of the subsurface and has been observed in vertical seismic profiling (VSP) and reflection data. De et al. (1994) report measurements of the Pand S-wave quality factors from VSP surveys and sonic logs. Klimentos (1995) measures compressional and shear attenuation from sonic logs in sandstone formations with variable oil, water, and gas...

نمودار تعداد نتایج جستجو در هر سال