نتایج جستجو برای: lever arm

تعداد نتایج: 71998  

Journal: :Biophysical journal 2011
V Ovchinnikov M Cecchini E Vanden-Eijnden M Karplus

Myosin VI (MVI) is a dimeric molecular motor that translocates backwards on actin filaments with a surprisingly large and variable step size, given its short lever arm. A recent x-ray structure of MVI indicates that the large step size can be explained in part by a novel conformation of the converter subdomain in the prepowerstroke state, in which a 53-residue insert, unique to MVI, reorients t...

2016
Tomonori Sawada Nobuhiro Kito Masaki Yukimune Kazuki Tokuda Kenji Tanimoto Masaya Anan Makoto Takahashi Koichi Shinkoda

[Purpose] Lateral wedge insoles reduce the peak external knee adduction moment and are advocated for patients with knee osteoarthritis. However, some patients demonstrate adverse biomechanical effects with treatment. In this study, we examined the immediate effects of lateral and medial wedge insoles under unilateral weight bearing. [Subjects and Methods] Thirty healthy young adults participate...

2017
Seunghwan Hong Ilsuk Park Ji-Sang Lee Kwangyong Lim Yoonjo Choi Hong-Gyoo Sohn

This paper proposes a practical calibration solution for estimating the boresight and lever-arm parameters of the sensors mounted on a Mobile Mapping System (MMS). On our MMS devised for conducting the calibration experiment, three network video cameras, one mobile laser scanner, and one Global Navigation Satellite System (GNSS)/Inertial Navigation System (INS) were mounted. The geometric relat...

Journal: :The American journal of physiology 1988
R L Lieber J L Boakes

The relationship between semitendinosus muscle force and knee joint kinematics during isometric torque production was examined in the frog (Rana pipiens) hindlimb. Passive muscle sarcomere length was monitored by laser diffraction during knee rotation, and joint center of rotation was determined later using principles of rigid body kinematics. Contractile force at the distal tibia, resulting fr...

Journal: :Frontiers in bioscience 2009
Sergey Y Bershitsky Michael A Ferenczi Natalia A Koubassova Andrey K Tsaturyan

The origin of reflections in the x-ray diffraction pattern from striated muscle and their use for understanding the structural organization of the contractile machinery are presented and discussed. Results of x-ray diffraction experiments obtained by a number of research groups using a variety of protocols revealed structural changes in contracting muscles which are interpreted in terms of mole...

Journal: :The EMBO journal 2008
Julie Ménétrey Paola Llinas Jérome Cicolari Gaëlle Squires Xiaoyan Liu Anna Li H Lee Sweeney Anne Houdusse

Myosin VI has an unexpectedly large swing of its lever arm (powerstroke) that optimizes its unique reverse direction movement. The basis for this is an unprecedented rearrangement of the subdomain to which the lever arm is attached, referred to as the converter. It is unclear at what point(s) in the myosin VI ATPase cycle rearrangements in the converter occur, and how this would effect lever ar...

Journal: :American journal of physiology. Cell physiology 2005
P J Griffiths M A Bagni B Colombini H Amenitsch S Bernstorff C C Ashley G Cecchi

M3 reflection intensity (I(M3)) from tetanized, intact skeletal muscle fiber bundles was measured during sinusoidal length oscillations at 2.8 kHz, a frequency at which the myosin motor's power stroke is greatly reduced. I(M3) signals were approximately sinusoidal, but showed a "double peak" distortion previously observed only at lower oscillation frequencies. A tilting lever arm model simulate...

Journal: :Current Biology 2008
James A. Spudich

A recent study has revealed an unexpected change in conformation of the myosin VI converter domain, essential for twisting the lever arm through a approximately 180 degrees rotation to achieve a large step along actin.

2006
Jaewon Seo Hyung Keun Lee Jang Gyu Lee Chan Gook Park

For more accurate navigation, lever arm compensation is considered. The compensation method for GPS and an odometer is introduced and new compensation methods are proposed for an odometer to consider the effect of coordinate transformation errors and the scale factor error. The methods are applied to a GPS/INS/odometer integrated system and the simulation and experimental results show its effec...

2007
Wayne Hu Daniel E. Holz Chris Vale

We discuss combining gravitational lensing of galaxies and the cosmic microwave background (CMB) by clusters to measure cosmographic distance ratios, and hence dark energy parameters. Advantages to using the CMB as the second source plane, instead of galaxies, include: a welldetermined source distance, a longer lever arm for distance ratios, typically up to an order of magnitude higher sensitiv...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید