نتایج جستجو برای: keywords motion correction

تعداد نتایج: 2309005  

2013
I-Fan Chen Chin-Hui Lee

A hierarchical framework is proposed to address the issues of modeling different type of words in keyword spotting (KWS). Keyword models are built at various levels according to the availability of training set resources for each individual word. The proposed approach improves the performance of KWS even when no training speech is available for the keywords. It also suggests an easier way to co...

Journal: :Journal of Object Technology 2007
Mourad Debbabi M. Fourati

boolean byte class double else extends final finally float if implements int interface long native new private public return short static super synchronized this throw throws transient try void volatile while ( ) [ ] { } ; , . = Figure 1: Java keywords.

2005
K. K. Wong A. Das M. N. Chong HONG KONG

Studies show that all the published work in flicker correction to date only deals with black and white motion pictures. In this paper, we will look into the problem of flicker correction in color motion pictures and propose a method to address this problem. The method is based on a simplified flicker parameter model developed by us in [5] which was originally used for flicker correction in blac...

Journal: :Magnetic resonance imaging 2007
Ning Xu J Michael Fitzpatrick Yong Li Benoit M Dawant David R Pickens Victoria L Morgan

As an extension of previous work on computer-generated phantoms, more accurate, realistic phantoms are generated by integrating image distortion and signal loss caused by susceptibility variations. With the addition of real motions and activations determined from actual functional MRI studies, these phantoms can be used by the fMRI community to assess with higher fidelity pre-processing algorit...

2011
Muhammad Usman Christoph kolbitsch Ghislain Vaillant David Atkinson Tobias Schaeffter Philip G. Batchelor Claudia Prieto

Introduction: Compressed Sensing (CS) has been demonstrated to reconstruct sparse MR images of adequate quality from highly undersampled data [1], resulting in reduced scan times. In MRI, extensive motion during the acquisition (e.g. respiratory motion in cardiac scans) can cause inconsistencies in the k-space data, introducing blurring and ghosting like motion artefacts in the reconstructed im...

Journal: :Magnetic resonance in medicine 2010
Lan Ge Aya Kino Mark Griswold James C Carr Debiao Li

First-pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate-gradient (CG) highly constrained back-projection reconstruction (HYPR) (SW-CG-HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath-hold. This work presents a non-model-base...

Journal: :Magnetic resonance in medicine 2013
Julian Maclaren Michael Herbst Oliver Speck Maxim Zaitsev

Motion correction in magnetic resonance imaging by real-time adjustment of the imaging pulse sequence was first proposed more than 20 years ago. Recent advances have resulted from combining real-time correction with new navigator and external tracking mechanisms capable of quantifying rigid-body motion in all 6 degrees of freedom. The technique is now often referred to as "prospective motion co...

Journal: :NeuroImage 2012
Vadim Zotev Han Yuan Raquel Phillips Jerzy Bodurka

We propose a method for retrospective motion correction of fMRI data in simultaneous EEG-fMRI that employs the EEG array as a sensitive motion detector. EEG motion artifacts are used to generate motion regressors describing rotational head movements with millisecond temporal resolution. These regressors are utilized for slice-specific motion correction of unprocessed fMRI data. Performance of t...

2014
Shireen Elhabian Yaniv Gur Clement Vachet Joseph Piven Martin Styner Ilana R. Leppert G. Bruce Pike Guido Gerig

Diffusion-weighted imaging (DWI) is known to be prone to artifacts related to motion originating from subject movement, cardiac pulsation, and breathing, but also to mechanical issues such as table vibrations. Given the necessity for rigorous quality control and motion correction, users are often left to use simple heuristics to select correction schemes, which involves simple qualitative viewi...