نتایج جستجو برای: ionic concentration

تعداد نتایج: 420760  

2014
Mohammadreza Hosseinpour Manouchehr Vossoughi Iran Alemzadeh

BACKGROUND In the recent study, optimum operational conditions of cathode compartment of microbial fuel cell were determined by using Response Surface Methodology (RSM) with a central composite design to maximize power density and COD removal. METHODS The interactive effects of parameters such as, pH, buffer concentration and ionic strength on power density and COD removal were evaluated in t...

2005
Abohachem Laguecir Serge Stoll

Monte Carlo simulations were used to investigate the conformational and electrical properties of isolated weak polyelectrolytes in the presence of an oppositely charged particle. Titrations curves were calculated to get an insight into the role of pH on the degree of ionization and conformation of isolated chains. The effect of ionic concentration and polyelectrolyte length on the titration cur...

Journal: :Nano letters 2005
Rohit Karnik Kenneth Castelino Rong Fan Peidong Yang Arun Majumdar

Conductance characteristics of nanofluidic channels (nanochannels) fall into two regimes: at low ionic concentrations, conductance is governed by surface charge while at high ionic concentrations it is determined by nanochannel geometry and bulk ionic concentration. We used aminosilane chemistry and streptavidin-biotin binding to study the effects of surface reactions on nanochannel conductance...

Journal: :Journal of colloid and interface science 2004
B M Razavizadeh M Mousavi-Khoshdel H Gharibi R Behjatmanesh-Ardakani S Javadian B Sohrabi

Mixtures of alkyltrimethylammonium bromide (CnTAB, n=12, 14, 16, 18) and Triton X-100 were studied at a range of mole fractions of ionic surfactant per nonionic surfactant. For each mixture, the cmc obtained from surface tension measurements differed from that obtained using potentiometry. The behavior of these mixed-surfactant systems showed three different regions with increasing total surfac...

Journal: :Journal of the Royal Society, Interface 2014
Georgina E Lang Peter S Stewart Dominic Vella Sarah L Waters Alain Goriely

Brain tissue swelling is a dangerous consequence of traumatic injury and is associated with raised intracranial pressure and restricted blood flow. We consider the mechanical effects that drive swelling of brain tissue slices in an ionic solution bath, motivated by recent experimental results that showed that the volume change of tissue slices depends on the ionic concentration of the bathing s...

Journal: :Journal of colloid and interface science 2015
Ran Peng Dongqing Li

Effects of ionic concentration gradient on electroosmotic flow (EOF) mixing of one stream of a high concentration electrolyte solution with a stream of a low concentration electrolyte solution in a microchannel are investigated numerically. The concentration field, flow field and electric field are strongly coupled via concentration dependent zeta potential, dielectric constant and electric con...

Journal: :The Journal of General Physiology 1965
S. Hagiwara

Giant muscle fibers 1 to 2 mm in diameter and 4 to 5 cm in length are found in the barnacle Balanus nubilus. The preparation offers an excellent opportunity for studying membrane mechanisms of excitation by controlling the internal ionic composition of the fiber. The internal ionic composition was altered by intracellular injection through a glass pipette longitudinally inserted into the fiber....

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

Journal: :Clinical chemistry 1970
G W Neff

The ion-sensitiveelectrodes used to measure Na, K, and Clin biological fluids have output voltages that are logarithmically related to ionic activity. This measured voltage also is linearly related to ionic concentration for the Na and Clelectrodes. Furthermore, the K electrode, which must be corrected for its Na sensitivity in whole blood or plasma, exhibits a linear characteristic between mea...

Journal: :The Journal of General Physiology 1958
Tomoaki Asano W. P. Hurlbut

Stimulation of intact or desheathed frog sciatic nerves produced an increase in the sodium content and a decrease in the potassium content of this tissue. In desheathed preparations the magnitudes of the changes in ionic contents decreased as the concentration of the potassium in the bathing solution was increased, while changing the external sodium concentration produced small effects on the i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید