نتایج جستجو برای: iodide ion selective electrode

تعداد نتایج: 461721  

2006
M. R. Ganjali

In this paper, a novel membrane triiodide sensor based on a charge-transfer complex of (1,3-diphenyldihydro-1H-imidazole-4,5-dionedioxime) with iodine (CTCI) as a membrane carrier is introduced. The best performance was obtained with a membrane containing 30% polyvinylchloride (PVC), 63% dibutylphthalate (DBP), 5% CTCI and 2% hexadecyltrimethylammonium bromide (HTAB). The electrode shows a Nern...

Abbas Afkhami, Atousa Bahiraei Mahdi Moradi Tayyebeh Madrakian,

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

H. Aghaie K. Zare M. Aghaie M. Arvand M. H. Felcri

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

Forogh Adhami Leila Hajiaghababaei Saeid Takalou

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2007
Qin Zhao Ruo Yuan Yaqin Chai Lan Xu Jiancun Chen Zhongxiu Zhang

A new highly selective iodide electrode incorporating a binuclear manganese(III) complex, bis(salicylaldehyde-aminopropanol)dichloroaceticdimanganese(III) [Mn(III)(2)-BSAPDCA], as a neutral carrier is described. The electrode displays an anti-Hofmeister selectivity sequence: iodide >> perchlorate > salicylate > thiocyanate > nitrate > bromide > nitrite > chloride > sulfate. The excellent select...

2017
Tanushree Ghosh Hyun-Joong Chung Jana Rieger

Conventional ion-selective electrodes with a liquid junction have the disadvantage of potential drift. All-solid-state ion-selective electrodes with solid contact in between the metal electrode and the ion-selective membrane offer high capacitance or conductance to enhance potential stability. Solution-casted chitosan/Prussian blue nanocomposite (ChPBN) was employed as the solid contact layer f...

E. Baghdar M. Aghaie M. Giahi M. H. Fekri S. Farhadi

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشگاه پیام نور مرکز - دانشکده علوم پایه 1388

در این پایان نامه جهت اندازه گیری پتانسیومتری کاتیونهای سرب pb2+ و نیکلni2+ ، الکترود یون گزین غشایی مبتنی بر پلی وینیل کلرید (pvc) و الکترودهای خمیر کربن با استفاده از دو یون دوست جدید به همراه نرم کننده و افزودنیهای یونی طراحی، ساخت و مورد بررسی قرار گرفت. در تهیه الکترود یون گزین سرب از لیگاند n,n بیس( سالیسیلیدین) 1و6 دی آمینو هگزان (nsah) در ترکیب الکترود خمیر کربنی استفاده شد. الکترود ف...

Journal: :Bulletin of the Chemical Society of Japan 1975

H. Khanmohammadi H. Shafie M. Darvishpour M. H. Fekri R. Aminameli

A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید