In this paper, synthetic jet actuators (SJAs) with three different orifice shapes (circular, square, and slot) the same cross-section area were investigated. The SJA efficiency (SJ) Reynolds number calculated based on time-mean reaction force measurement. momentum velocity was measured hot-wire anemometry additionally, sound pressure level (SPL) measured. equal maximally to 5.3% for each shape,...