نتایج جستجو برای: hip implants

تعداد نتایج: 115741  

Journal: :Orthopaedics & traumatology, surgery & research : OTSR 2012
J-F Lardanchet J Taviaux D Arnalsteen A Gabrion P Mertl

INTRODUCTION The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip replacement prompted the development of large-diameter heads that more closely replicated the normal hip anatomy, with the goal of improving prosthesis stability. However, the blood release of metal ions due to wear at the bearing surfaces and the high rate of groin pain seen with larg...

2012
Kazutaka So Kumiko T Kanatani Yutaka Kuroda Takashi Nakamura Shuichi Matsuda Haruhiko Akiyama

BACKGROUND AND PURPOSE Cementless total hip arthroplasty is currently favored by many orthopedic surgeons. The design of the porous surface is critically important for long-term fixation. We examined the clinical and radiographic outcome of the cementless titanium hip implant with a bottom coating of apatite-wollastonite containing bioactive glass ceramic. METHODS We retrospectively reviewed ...

2017
Soong Joon Lee Jeong Joon Yoo Hee Joong Kim

BACKGROUND Total hip arthroplasty with subtrochanteric shortening osteotomy is widely performed for high hip dislocation. However, suboptimal leg length discrepancy correction and nonunion of the osteotomy site remain concerns. Although total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy was introduced, cemented implants have been more commonly used than contem...

Journal: :Acta orthopaedica Belgica 2015
Faiz Khan Tayyab Ahmad Finbarr Condon Brian Lenehan

Digital templating of x-rays for total hip arthroplasty is used routinely for pre-operative planning. This is to assure that appropriately sized implants are selected to replicate patient's hip biomechanics. Multiple studies have shown that templating does not always correspond to the final implants used. The aim of this study was to assess the suitability of the x-rays taken pre-operatively fo...

2011
Carlo L Romanò Delia Romanò Enzo Meani Nicola Logoluso Lorenzo Drago

BACKGROUND Outcome data on two-stage revision surgery for deep infection after septic hip arthritis are limited and inconsistent. This study presents the medium-term results of a new, standardized two-stage arthroplasty with preformed hip spacers and cementless implants in a consecutive series of adult patients with septic arthritis of the hip treated according to a same protocol. METHODS Nin...

2016
Benjamin Kendrick

A s populations increase in size, and as total hip arthroplasty is increasingly performed in younger patients, the burden on healthcare systems grows. Implant survivorship beyond two decades is becoming an imperative. Unfortunately, many hip implants have been introduced—often as minor modifications of a successful design—only to fail catastrophically. Joint registries pioneered by the Scandina...

Journal: :Journal of the mechanical behavior of biomedical materials 2011
A Chandra J J Ryu P Karra P Shrotriya V Tvergaard M Gaisser T Weik

Stress dependent electrochemical dissolution is identified as one of the key mechanisms governing surface degradation in fretting and crevice corrosion of biomedical implants. The present study focuses on delineating the roles of mechanical stress and chemical conditions on the life expectancy of modular hip implants. First, material removal on a stressed surface of Ti6Al4V subjected to single ...

Journal: :Clinical orthopaedics and related research 2004
S J MacDonald

The metal-on-metal bearing couple is having a resurgence in clinical applications seen in total hip and hip resurfacing technologies. The most noteworthy advantage of a metal-on-metal implant is the improved wear characteristics seen in vitro on wear simulators and in vivo with retrieved implants. All bearings have disadvantages, and a metal-on-metal bearing is no exception. Concerns exist rega...

Journal: :BMJ 2011
Deborah Cohen

It is one of the biggest disasters in orthopaedic history, according to one senior surgeon. On 24 August 2010, DePuy, a subsidiary of American giant Johnson and Johnson, recalled its ASR (articular surface replacement) hip prostheses from the market. The recall followed years of denial by the company that the ASR implants had caused pain and disability in patients. In a statement to the BMJ, De...

2015
Reshid Berber Michael Khoo Erica Cook Andrew Guppy Jia Hua Jonathan Miles Richard Carrington John Skinner Alister Hart

BACKGROUND AND PURPOSE Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time. PATIENTS AND...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید