نتایج جستجو برای: goldmann applanation tonometer

تعداد نتایج: 2316  

2016
Gabriela González Castro Alastair D. Fitt John Sweeney

Ophthalmologists rely on a device known as the Goldmann applanation tonometer to make intraocular pressure (IOP) measurements. It measures the force required to press a flat disc against the cornea to produce a flattened circular region of known area. The IOP is deduced from this force using the Imbert-Fick principle. However, there is scant analytical justification for this analysis. We presen...

Journal: :International journal of ophthalmology 2013
Fereydoun Farrahi Farideh Sharifipour Mohammad Malekahmadi Bahman Cheraghian

AIM To compare the accuracy of IOPen rebound tonometer with Goldmann applanation tonometer (GAT) in individuals with low, normal and high intraocular pressure (IOP) and to evaluate the effect of central corneal thickness (CCT) on IOP measurements. METHODS This cross-sectional study consisted of 159 participants. IOP of one eye of each subject was measured consecutively with IOPen and GAT. The...

2015
Joanna Wasielica-Poslednik Christina Butsch Christina Lampe Heike Elflein Julia Lamparter Veronika Weyer Susanne Pitz Sanjoy Bhattacharya

AIMS To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA). METHODS MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in...

2013
Ian G. Beasley Deborah S. Laughton Benjamin J. Coldrick Thomas E. Drew Marium Sallah Leon N. Davies

Purpose. To examine the influence of positional misalignments on intraocular pressure (IOP) measurement with a rebound tonometer. Methods. Using the iCare rebound tonometer, IOP readings were taken from the right eye of 36 healthy subjects at the central corneal apex (CC) and compared to IOP measures using the Goldmann applanation tonometer (GAT). Using a bespoke rig, iCare IOP readings were al...

2016
John G Lawrenson Ian E Murdoch Ian Murdoch

Title Evaluation of a new rebound tonometer for self-measurement of intraocular pressure Subtitle Self-measurement using Icare Home showed good agreement with Goldmann applanation tonometry. Icare Home self-measurement was well accepted and reliable results obtained by 3 in 4 subjects, suggesting potential use for home measurement of intraocular pressure. Number of references = 26 Number of sup...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید