نتایج جستجو برای: glaucoma drainage implants

تعداد نتایج: 120783  

2017
Young Kook Kim Kyeong Ik Na Jin Wook Jeoung Ki Ho Park

PURPOSE To evaluate whether defects in cervical lymphatic drainage influence the intraocular pressure (IOP)-lowering effect of latanoprost in patients with primary open-angle glaucoma (POAG) who have undergone unilateral radical neck dissection (uRND). METHODS We enrolled (1) bilateral POAG patients who had started (bilateral) latanoprost (0.005%) monotherapy prior to their uRND and (2) treat...

Journal: :The British journal of ophthalmology 2001
Sheng Lim

AIMS (I) To examine whether small holes produced by 248 nm excimer laser ablation in a polymer substrate could consistently produce a pressure drop in the desired target range (5-15 mm Hg) at physiological aqueous flow rates for use as an internal flow restrictor in a glaucoma drainage device, and (ii) to investigate whether external leakage could be reduced in comparison with conventional tube...

Journal: :Journal of glaucoma 2018
Hamed Esfandiari Tarek Shazly Susannah Waxman Sushma Kola Kevin B Kaplowitz Eric N Brown Nils A Loewen

PURPOSE To apply propensity score matching to Ahmed glaucoma drainage implants (AGI) to trabectome-mediated ab interno trabeculectomy (AIT). Recent data suggests that AIT can produce results similar to AGI traditionally reserved for more severe glaucoma. METHODS AGI and AIT patients with at least one year of follow-up were included. The primary outcome measures were intraocular pressure (IOP)...

2014
Naomi SJ Ting James FT Li Yim Jia Y Ng

Glaucoma is the second highest cause of blindness worldwide with an estimated half of the glaucoma population unaware of their disease. To date, intraocular pressure is the most important modifiable risk factor and lowering it has been proven to reduce progression of visual field loss associated with glaucoma. Different strategies are available to lower intraocular pressure and include medical,...

2010
Ghee Soon Ang Yi Wei Goh Augusto Azuara-Blanco

Patients with spontaneous lens dislocation and glaucoma can be challenging to manage. We present a forty-six year old Caucasian lady who was referred with bilateral high intraocular pressure, and was subsequently diagnosed with glaucoma in association with lens dislocation and Marfan syndrome. Baerveldt glaucoma drainage device tubes were inserted in both eyes due to poor response to medical th...

2017
David Z Chen Chelvin C A Sng

Microinvasive glaucoma surgery (MIGS) is emerging as a new therapeutic option for glaucoma patients who wish to reduce their medication burden and avoid the postoperative complications of conventional glaucoma filtration surgery. These devices differ in terms of their efficacy and safety profile. Schlemm's canal devices have the most favorable safety profile at the compromise of modest efficacy...

Journal: :European journal of ophthalmology 2005
E Gutiérrez-Díaz M Montero-Rodríguez E Mencía-Gutiérrez A Cabello J Monescillo

PURPOSE Conjunctival erosion in glaucoma drainage device surgery can be prevented by the use of patch grafts to cover the extraocular portion of the tube. Several materials can be used, among them human preserved fascia lata. METHODS The authors present a case of a failed Ahmed glaucoma valve due to encapsulation of the bleb, in which the fascia lata patch placed to cover the tube was removed...

Journal: :Journal of glaucoma 2005
Anand B Joshi Richard K Parrish William F Feuer

PURPOSE To determine the preference of members of the American Glaucoma Society for the use of antifibrotic agents (mitomycin C or 5-fluorouracil or both) and glaucoma drainage devices in ten clinical settings. MATERIALS AND METHODS Voluntary written survey of the American Glaucoma Society. RESULTS American Glaucoma Society (AGS) members continue to report preference for mitomycin C use in ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید