نتایج جستجو برای: fast response time

تعداد نتایج: 2852338  

Journal: :asian journal of sports medicine 0
maman paul faculty of sports medicine and physiotherapy, guru nanak dev, university, amritsar-143005, india kanupriya garg jaspal singh sandhu

conclusion the results of the study suggest that biofeedback training may help to train stressed athletes to acquire a control over their psychophysiological processes, thus helping an athlete to perform maximally. results two way repeated measure anova was used to simultaneously compare within and between group differences. response time, concentration, heart rate variability, respiration rate...

Iryna Hunka Yaroslav Bazel Zholt Kormosh,

A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...

A. Khaki Sedigh A.S. Ashtari

Model predictive controller is widely used in industrial plants. Uncertainty is one of the critical issues in real systems. In this paper, the direct adaptive Simplified Model Predictive Control (SMPC) is proposed for unknown or time varying plants with uncertainties. By estimating the plant step response in each sample, the controller is designed and the controller coefficients are directly ca...

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

A. Haghighi, H. M. Vali Samani, M. H. Ranginkaman,

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

E. Baghdar M. Darvishpour M.H. Fekri

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

Electric vehicle charging in the distribution network is one of the common techniques for technical and economic management of energy distribution, which, if implemented properly, will bring several benefits such as reducing network peak load, charging costs reduction, loss minimization, and etc. In most traditional charging methods, the constraints of fully charging electric vehicles at depart...

Journal: :journal of emergency practice and trauma 0
afsaneh esmaeili ranjbar department of emergency medicine, kerman university of medical sciences, kerman, iran masoud mayel department of emergency medicine, kerman university of medical sciences, kerman, iran mitra movahedi department of emergency medicine, kerman university of medical sciences, kerman, iran faezeh emaeili ranjbar department of biology, kerman branch of islamic azad university, kerman, iran amirhossein mirafzal department of emergency medicine, kerman university of medical sciences, kerman, iran

objective: most previous retrospective studies failed to show a consistent association between pre-hospital time intervals and mortality in trauma patients, bringing the recommendation of “transport fast to increase survival” under question. the aim of this study was to evaluate the association of response time, scene time, and transport time with 24-hour in-hospital mortality.   methods: in th...

Journal: :the modares journal of electrical engineering 2006
mohammad orvatinia faramarz hossein-babaei

gas sensitive metal oxide layers used in fabrication of resistive gas sensors are prepared by different deposition techniques. the technical data reported on some basic and practically important specifications of these devices, although fabricated based on the same gas sensitive oxide, are anomalously different. the influence of the fabrication technique used for the deposition of the gas sensi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید