نتایج جستجو برای: fast neutrons

تعداد نتایج: 248250  

Journal: :Journal of radiation research 1999
M Hoshi S Endo J Takada M Ishikawa Y Nitta K Iwatani T Oka S Fujita K Shizuma H Hasai

There has been a large discrepancy between the Dosimetry system 1986 (DS86) and measured data, some of which data in Hiroshima at about 1.5 km ground distance from the hypocenter are about 10 times larger than the calculation. Therefore its causes have long been discussed, since it will change the estimated radiation risks obtained based on the Hiroshima and Nagasaki data. In this study the con...

Journal: :Research and development technical report. United States. Naval Radiological Defense Laboratory, San Francisco 1962
L J COLE P C NOWELL

Introduction: The utilization of high-energy photons in the medical linear accelerator can lead to photoneutron production. This study aimed to evaluate the effect of the physical components of the head, including flattening filter (FF) andmultileaf collimator (MLC), as well as the dependence of therapeutic field size on the photoneutron spectrum, dose, and flux. <str...

Journal: :Proceedings of the Royal Society of London. Series A, Mathematical and physical sciences 1947
W H RAMSEY

1. Introduction. Recent experiments by Amaldi arid his collaborators on the scattering of high-energy neutrons (of 10—15MeV.) by protons (2) have disclosed a considerable anisotropy in the angular distribution of the scattered particles. Theoretical discussions of this problem show an interesting feature in that the results depend sensitively on the basic assumptions involved with regard to the...

Journal: :International journal of radiation oncology, biology, physics 1978
P Todd J P Geraci P S Furcinitti R M Rossi F Mikage R B Theus C B Schroy

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2015
J Scherzinger J R M Annand G Davatz K G Fissum U Gendotti R Hall-Wilton E Håkansson R Jebali K Kanaki M Lundin B Nilsson A Rosborge H Svensson

Shielding, coincidence, and time-of-flight measurement techniques are employed to tag fast neutrons emitted from an (241)Am/(9)Be source resulting in a continuous polychromatic energy-tagged beam of neutrons with energies up to 7MeV. The measured energy structure of the beam agrees qualitatively with both previous measurements and theoretical calculations.

Journal: :Journal of radiation research 2001
Y Murata T Muroyama Y Kawabata M Yamamoto K Komura

Specific activities (Bq/g-element) of residual neutron-induced radionuclides by the JCO criticality accident were measured for soil, concrete block and chemical reagent samples collected in the JCO campus. Induced radionuclides such as 24Na, 46Sc, 54Mn, 59Fe, 60Co, 65Zn, 82Br, 122Sb, 134Cs and 140La were detected in the samples, depending on the ground distance from the accident point and the s...

Journal: :British medical journal 1978
A Franklin J S Uff J Spencer

2004
G. Adamiec M. P. Iñiguez A. Lorente M. Voytchev E. Gallego José Gutiérrez

The properties as a neutron detector of a silicon photodiode of type Hamamatsu S3590-02 in conjunction with a multi-channel analyser Alphatron-3C were investigated in an Am-Be calibration field at the department of nuclear engineering at the University of Madrid. Since the photodiode is sensitive to charged particles, we covered it with two types of converters to enable its response to thermal ...

Journal: :The British journal of ophthalmology 1976
J Roth N Brown M Catterall A Beal

The study of 93 eyes receiving neutron irradiation establishes the character of the ophthalmic complications of neutron. Significant changes are produced in the eyelids, conjunctiva, and cornea, but the production of cataract is relatively unimportant. No reaction was seen after neutron treatment that had not already been seen after chi or gamma radiation. That the unavoidable damage is similar...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید