نتایج جستجو برای: distal interlocking screw
تعداد نتایج: 88021 فیلتر نتایج به سال:
of diaphyseal long bone fractures. Interlocking nails have transverse cannulations that accommodate transcortical screws, allowing surgeons to firmly fix the rod within the medullary canal, thereby effectively neutralizing bending, rotational, and axial forces that act on fractures. Interlocking nails have become increasingly To counter axial and rotational forces, intramedullary nails were dev...
Abstract Background: Reamed interlocking intramedullary nailing of the tibia is a procedure for the treatment of a non-infected tibial non:::union:::. The purpose of this clinical study was to evaluate the outcome of this method as a treatment of tibial non:::union:::. Methods: Twenty-nine patients with non:::union::: after initial therapy for tibial fracture were retrospectively assessed...
A subtrochanteric femur fracture after cannulated screw fixation of a femoral neck fracture is a devastating complication. We hypothesized that an apex-distal screw orientation would tolerate higher loads to subtrochanteric fracture. Human cadaveric femora were instrumented with three cannulated screws in either an apex-distal or an apex-proximal configuration. Specimens were loaded along the m...
The ability of an interlocking screw fixation technique to minimize bone loss related to stress shielding in the tibia was investigated and compared to the abilities of cement and press-fit fixation. Full bony ingrowth has been associated with greater stress shielding than partial ingrowth; therefore, the effect of intimate bonding of the stem to bone on subsequent bone loss was also studied. A...
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
BACKGROUND Fixation of an anterior cruciate ligament graft at the joint line with an interference screw restores anterior laxity better than low-stiffness distal fixation with double staples and sutures tied to a post at implantation in porcine bone. HYPOTHESIS Fixation of an anterior cruciate ligament graft with a high-stiffness distal fixation device restores anterior laxity and knee stiffn...
BACKGROUND Complications related to extensor tendons have begun to increase with the use of volar plates in the treatment of distal radius fractures. In this study, we aimed to compare four-plane radiography and ultrasonography in the evaluation of dorsal cortex screw penetration following volar plate fixation. METHODS We recruited 47 patients (33 males, 14 females, mean age 37.4 years; range...
In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...
BACKGROUND Medial patellofemoral ligament (MPFL) reconstruction in adults often utilizes screw fixation in the distal femur. The aim was to define the safety of similar fixation in young patients, with respect to their open physis. PURPOSE To define the age-related relationship between the femoral insertion of the MPFL and the medial aspect of the distal femoral physis on magnetic resonance i...
Our purpose was to report the use of an interlocking nail-hybrid external fixator construct to correct distal femoral deformities in three dogs. Radiographs, computed tomography and a three-dimensional model were used to plan the surgical procedure. A femoral osteotomy or ostectomy was performed at the level of the centre of rotation of angulation in all three dogs. Angular and rotational defor...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید