نتایج جستجو برای: disinfection by
تعداد نتایج: 7049288 فیلتر نتایج به سال:
BACKGROUND Stethoscopes are contaminated with bacteria, but predictors of stethoscope disinfection frequency are unknown. We sought to describe health care provider stethoscope disinfection attitudes and practices and determine predictors of frequent disinfection. METHODS We used an anonymous online survey of nurses, nurse practitioners, and physicians at a pediatric hospital. We assessed fre...
Increased attention has been focused on disinfection by housekeepers, but few data are available on disinfection of equipment by nurses. We used adenosine triphosphate bioluminescence assays and aerobic cultures to assess the cleanliness of portable medical equipment disinfected by nurses between each patient use. We found that the equipment was not being disinfected as per protocol and that ed...
A standardized protocol for the evaluation of hand disinfection by surgical scrub formulations was applied to volunteers in a multicenter trial. Povidone iodine (PVI), chlorhexidine (CHX), and a nonmedicated soap (NMS) were tested. The scrubbing procedure involved three daily hand washings for five consecutive days; surviving bacteria were counted daily after being collected in a suitable neutr...
A recent research letter on the limited efficacy of alcohol-based hand gels has alerted the global infection control community and raised the question of the true significance of data obtained according to EN 1500. It has been described that a 1 min simple hand wash reduces artificial contamination of hands by a log(10) reduction factor of 2.8 and a 1 min reference hand disinfection with 2-prop...
This study assessed the inhaled dose of alcohol during hand disinfection. Experiments were conducted with two types of hand rub using two hand disinfection procedures. Air samples were collected every 10 s from the breathing zone, by bubbling through a mixture of K(2)Cr(2)O(7) and H(2)SO(4). The reduction of dichromate ions in the presence of alcohols was followed by UV-vis spectrophotometry. T...
as Pseudomonas, Acinetobacter, and Staphylococcus that appropriate disinfection can reduce these pathogens. The aim of this study was to evaluate the effect of different disinfectants on Gram-negative bacteria isolated from the surface of accidents and burn hospital in Yazd. Materials and Methods: In this study, 240 samples were randomly collected from different parts of acciden...
Background & Aim: Hemodialysis centers are highly susceptible to nasocomial infections due to application of hemodialysis machines, medical equipment, and invasive techniques and devices. This research was carried out in order to evaluate methods of infection control using by staff of hemodialysis centers.Methods & Materials: In this descriptive study, all hemodialysis units in hospitals of Teh...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید